QuickSpecs HP BladeSystem c7000 Enclosure
Overview
HP BladeSystem c7000 Enclosure
HP BladeSystem c7000 Enclosure - Front View HP BladeSystem c7000 Enclosure - Rear View
1-16. Device Bays 1-16 1. Active Cool 200 Fans and Fan Bays
17-22. Power Supply Bays 1-6 2. Interconnect Module Bays
23. Insight Display 3. BladeSystem Onboard Administrator (left) and optional
redundant Onboard Administrator (right)
4. Power Inputs (single-phase 200-240V AC model shown)
What's New
Support for the HP Virtual Connect 16Gb 24-Port Fibre Channel Module for c-Class BladeSystem
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 1
QuickSpecs HP BladeSystem c7000 Enclosure
HP BladeSystem c-Class Overview
HP BladeSystem c-Class A HP BladeSystem solutions start with either a BladeSystem c7000 or c3000 enclosure. For the c7000
c7000 Enclosure enclosure, key enclosure options include hot-plug power supplies, power input module, hot-plug HP
Active Cool 200 Fans, and an optional redundant BladeSystem Onboard Administrator module. Once
the enclosure and its key components have been selected, the following components can be added:
interconnect modules, HP ProLiant and Integrity server blades, expansion blades, and HP OneView or
Insight Control management software. For information on these options please visit:
http://www.hp.com/go/bladesystem.
NOTE: HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen9 ProLiant and Integrity
server blades, subject to support requirements of the Onboard Administrator. If configuring an
enclosure with only Gen9 server blades, Onboard Administrator firmware 4.11 or greater is required. If
configuring an enclosure with a mix of Gen9 and earlier server blades, G6 to Gen9 is supported and
requires Onboard Administrator firmware 4.30 or greater. In addition to these requirements, the
Onboard Administrator firmware must be a version that supports all the components in the enclosure.
HP recommends the current firmware whenever possible for maximum compatibility and stability.
Updating the Onboard Administrator firmware may also require other subsystem firmware upgrades.
For further information, please see the HP Service Pack for ProLiant (SPP) website and the HP Support
Center documents “HP ProLiant Server Blades - Compatibility with HP BladeSystem c7000 and c3000
Enclosures and Firmware” and ”ProLiant Gen9 Servers - Onboard Administrator Firmware Version 4.11
(or Later) Support for Gen9 Server Blades and Possible Issues That May Arise”.
A BladeSystem c7000 enclosure holds up to 16 server blades and up to 8 expansion blades (not
exceeding 16 total blades total) plus redundant network and storage interconnects. It includes a
shared, multi-terabit high-speed midplane for wire-once connectivity of server blades to network and
shared storage. Power is delivered through a pooled power backplane that ensures the full capacity of
the redundant hot-plug power supplies is available to all blades.
Each c7000 enclosure is built with the following functions:
Up to 16 half-height server blades, 8 full-height server blades, and/or 8 expansion blades per
enclosure (not exceeding 16 total blades).
NOTE: For information on mixing half-height server blades, full-height server blades, and
expansion blades, please see the section titled "Device Bay and Fan Bay Numbering and
Population Guidelines" later in this document.
Up to 4 redundant interconnect I/O fabrics (Ethernet, Fibre Channel, InfiniBand, iSCSI, SAS,
etc.) supported simultaneously within the enclosure.
Choice ofsingle-phase high-line AC, three-phase high-line AC, single-phase high voltage AC, -
48V DC, or high voltage DC power options for flexibility in connecting to datacenter power.
HP Thermal Logic technology to minimize power consumption and reduce cooling.
A minimum of four hot-plug HP Active Cool 200 Fans. For additional capacity, redundancy,
and improved power consumption and acoustics, Active Cool 200 Fan kits can be added for a
maximum of 10 fans.
Redundant hot-plug cooling, redundant hot-plug power supplies, redundant connections,
redundant interconnect modules, and optional redundant BladeSystem Onboard
Administrator management module.
An BladeSystem Onboard Administrator management module is built in to the enclosure with the
following functions:
Robust, multiple enclosure setup and control.
Reports asset and inventory information for the devices in the enclosure.
Reports thermal and power information, including real-time actual power usage per server
and per enclosure.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 2
QuickSpecs HP BladeSystem c7000 Enclosure
HP BladeSystem c-Class Overview
Front-mounted Insight Display for easy management within the datacenter.
Integrated access to all server blade iLOs from a single cable.
Provides integrated access to interconnect bay device management ports from the single
BladeSystem Onboard Administrator cable.
Single sign-on capability for all devices in the enclosure
Role-based security locally and/or with LDAP directory services.
Provides a wizard-based initial setup process for easy configuration.
A BladeSystem c7000 enclosure provides the following benefits:
With local and remote hardware management integrated across the solution, one full
enclosure can be managed as easily as one server.
Management and network interconnects extend scalability beyond a single enclosure,
allowing resources to be pooled and shared across multiple enclosures.
Accommodates multiple server and network designs in one enclosure.
Lower costs per server in comparison to rack-mounted servers.
Lower power consumption in comparison to rack-mounted servers.
Lower airflow requirements in comparison to rack-mounted servers.
Reduced and simplified cabling in comparison to rack-mounted servers.
Investment protection supporting G1 through Gen9 server blades.
NOTE: HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen9 ProLiant and
Integrity server blades, subject to support requirements of the Onboard Administrator. If
configuring an enclosure with only Gen9 server blades, Onboard Administrator firmware 4.11
or greater is required. If configuring an enclosure with a mix of Gen9 and earlier server
blades, G6 to Gen9 is supported and requires Onboard Administrator firmware 4.30 or
greater. In addition to these requirements, the Onboard Administrator firmware must be a
version that supports all the components in the enclosure. HP recommends the current
firmware whenever possible for maximum compatibility and stability. Updating the Onboard
Administrator firmware may also require other subsystem firmware upgrades. For further
information, please see the HP Service Pack for ProLiant (SPP) website and the HP Support
Center documents “HP ProLiant Server Blades - Compatibility with HP BladeSystem c7000
and c3000 Enclosures and Firmware” and ”ProLiant Gen9 Servers - Onboard Administrator
Firmware Version 4.11 (or Later) Support for Gen9 Server Blades and Possible Issues That
May Arise”.
HP BladeSystem c-Class For customers that need a smaller blade system, the HP BladeSystem c-Class c3000 Enclosure is the
c3000 Enclosure perfect solution. Supporting up to 8 blades and 4 interconnects, the c3000 enclosure provides an ideal
solution for small and medium businesses and remote sites. For more information please visit:
http://www.hp.com/go/bladesystem.
HP ProLiant & Integrity Delivering best-in-class performance, choice and reliability on AMD Opteron™, Intel® Xeon® and Intel®
Server Blades Itanium ® processors for Windows, Linux, Solaris, OpenVMS or HP-UX based servers; the HP portfolio
of server blades supports a variety of application requirements for scale-out architectures. HP offers
one-, two-, four- , or eight processor server blades, with the widest range of performance, and form
factors. For more information please visit: http://www.hp.com/go/bladesystem.
HP D2200sb Storage Do you need a direct attached or shared storage solution within your BladeSystem enclosure?
Blade
Direct attached storage
The D2220sb Storage Blade delivers direct attached storage for c-Class Gen8 and greater server
blades with support for up to twelve hot plug small form factor (SFF) SAS or SATA Midline hard disk
drives or SAS/SATA SSDs. The enclosure backplane provides a PCI Express connection to an adjacent c-
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 3
QuickSpecs HP BladeSystem c7000 Enclosure
HP BladeSystem c-Class Overview
Class server blade and enables high performance storage access without any additional cables. The
D2220sb Storage Blade features an onboard Smart Array P420i controller with 2GB flash-backed write
cache for increased performance and data protection. Up to eight D2220sb storage devices can be
supported in a single BladeSystem c7000 Enclosure for up to 115.2 TB of capacity.
Two ways to create shared storage with the D2220sb
Use HP StoreVirtual VSA software to turn the D2220sb into an iSCSI SAN for use by all servers in the
enclosure and any server on the network. HP VSA software is installed in a virtual machine on a
VMware ESX host server adjacent to the D2220sb. HP StoreVirtual VSA turns the D2220sb into a
scalable and robust iSCSI SAN, featuring storage clustering for scalability, network RAID for storage
failover, thin provisioning, snapshots, remote replication, and cloning. Expand capacity within the
same enclosure or to other BladeSystem enclosures by adding additional D2220sb Storage Blades and
HP VSA licenses. A cost effective bundle of the D2220sb Storage Blade and a HP StoreVirtual VSA
license makes purchasing convenient. If storage needs increase, add HP P4300 or P4500 systems
externally and manage everything via a single pane of glass.
The HP StoreEasy 3830 and 3840 Gateway Storage Blades are flexible storage server solutions for
BladeSystem environments. Combine the StoreEasy 3830 or 3840 with the D2220sb Storage Blade to
enable file serving and iSCSI shared storage inside the BladeSystem enclosure.
NOTE: The D2220sb requires a c7000 Enclosure configuration with 10 fans.
For more information, please visit:
http://h18004.www1.hp.com/products/quickspecs/14507_na/14507_na.html.
HP Ultrium Tape Tape blades are ideal for HP BladeSystem c-Class customers who need a data protection solution but
Blades are not connected into a storage area network (SAN). They provide direct attach data protection for
the adjacent server and network backup protection for all other data within the enclosure. The HP tape
blades are the industry's first bladed tape drives and are developed exclusively for the BladeSystem c-
Class enclosures.
For more information, please visit:
http://h18000.www1.hp.com/products/quickspecs/12729_na/12729_na.html.
Dynamic Power HP Dynamic Power Capping is the industry's first power capping solution that lets you reclaim trapped
Capping power and cooling capacity without putting electrical infrastructure or server performance at risk. The
enclosure Dynamic Power Cap will be shared amongst all of the installed devices and individual server
caps will be changed to match the server load. This will optimize the performance of the servers while
ensuring that the enclosure stays below the cap value.
Rack Airflow Rack 10000 G2 series cabinets
Requirements The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The G2 10000 Series Racks provide enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
NOTE: For operation with the -48VDC input module, the G2 1000 Series Rack Extension is required to
allow DC power cabling to be installed.
CAUTION: For the complete list of installation requirements, please see the “HP BladeSystem c-Class
Site Planning Guide” at http://www.hp.com/support.
Third-party racks
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your server rack includes closing front and rear doors, you must have
a minimum of 65% free area compared to the total area of the door evenly distributed from
top to bottom to permit adequate airflow.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 4
QuickSpecs HP BladeSystem c7000 Enclosure
HP BladeSystem c-Class Overview
Front door: The clearance from face of rack to inside of the front door must be a minimum of
77 mm (3 in).
Rear door: The clearance between the rear of the enclosure and the rear rack door must be a
minimum of 175 mm (6.9 in) to accommodate system cabling.
Side: The clearance between the installed rack component and the side panels of the rack
must be a minimum of 70 mm (2.75 in).
Width: 483 mm (19 in)
Depth: Maximum clearance between front and rear RETMA rails is 864 mm (34 in). Minimum
clearance for round-hole racks is 627 mm (24.7 in). Minimum clearance for square-hole racks
is 635 mm (25 in).
The rack must be able to accept the adjustable rack rails that are shipped with each
enclosure:
o Minimum rail length: 635 mm (25 in)
o Maximum rail length: 864 mm (34 in)
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
CAUTION: For the complete list of installation requirements, please see the “HP BladeSystem c-Class
Site Planning Guide” at http://www.hp.com/support.
Factory Express HP Factory Express offers configuration, customization, integration and deployment services for HP
Portfolio for Servers servers and storage products. Customers can choose how their factory solutions are built, tested,
and Storage integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging and custom packaging. HP products supported through Factory Express include: a wide array
of servers and storage: HP Integrity, HP ProLiant & HP ProLiant & Integrity Server Blades, HP
BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and
configurable network switches.
For more information on Factory Express services for your specific server model please contact your
sales representative or go to: http://www.hp.com/go/factory-express.
HP Simple Configurator SCE is a guided self-service tool to help sales and non-technical people provide customers with initial
configurations in 3 to 5 minutes. You may then send the configuration on for configuration help, or use
in your existing ordering processes. If you require "custom" rack configuration or configuration for
products not available in SCE, please contact HP's Customer Business Center or an Authorized Partner
for assistance. http://www.hp.com/products/configurator.
HP Insight Management Insight Management Managing the growing number of servers can be complex and expensive
software for your organization. IT managers need to address changing business
needs with tools that meet the challenges of managing today's complex
Datacenters.
HP Insight Management lowers the cost of running your HP ProLiant
servers by providing you with best-in-class management tools, including
HP Insight Control, HP Virtual Connect Enterprise Manager (VCEM), and HP
Insight Dynamics / Matrix Operating Environment. Insight Management
increases your productivity and reduces your operating costs to get you
higher value from your HP ProLiant servers.
Electronic download of Insight Management Media
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 5
QuickSpecs HP BladeSystem c7000 Enclosure
HP BladeSystem c-Class Overview
Insight Management software media is available for free download (not
including license entitlement certificates) at this website:
http://www.hp.com/go/insightupdates.
Software media available for download includes:
HP Insight Control
HP Insight Control for Microsoft® System Center
HP Insight Control for VMware vCenter Server
HP Virtual Connect Enterprise Manager (VCEM)
HP Insight Dynamics / Matrix Operating Environment
Customers will receive an Insight Control or Insight Dynamics license
entitlement certificate via physical shipment or email. The license
entitlement certificate must be redeemed online or via fax in order to
obtain the license activation key(s).
One year of 24x7 Software Technical Support and Updates are included
with your purchased licenses.
HP provides a complete range of installation and support services to
ensure the successful deployment and operations of your server
infrastructure. For more information about support services and licensing
options, see the following website:
http://www.hp.com/go/insightsoftware
Insight Software Media Kit (DVDs)
Physical media (DVDs) are also available for purchase from HP or from your
authorized reseller
Service Pack for Customers should use the HP Service Pack for ProLiant (SPP) to perform
ProLiant (SPP) firmware, driver, and related software updates.
SPP main webpage: www.hp.com/go/spp
SPP downloads webpage: www.hp.com/go/spp/download
HP Integrated HP Integrated Lights-Out (iLO) simplifies server setup, health monitoring,
Lights-Out (iLO) power and thermal control, and lights-out remote administration of
ProLiant ML, DL, and BL servers. HP iLO functions without additional
software and can be accessed from any location via a web browser. HP iLO
works hand-in-hand with HP Systems Insight Manager, Insight Control and
Insight Dynamics for ProLiant, helping customers unleash the value of the
ProLiant platform and deliver the highest possible quality of IT service. For
more information, visit: www.hp.com/go/iLO.
HP Insight Control HP Insight Control, a product option, delivers essential infrastructure
management that can help save time and money by making it easy to
deploy, monitor, remote control, and optimize your IT infrastructure
through a single, simple management console. For more information, see
http://www.hp.com/go/insightcontrol.
HP Insight Control includes one year of 24 x 7 HP Software Technical
Support and Update Service ensuring rapid access to HP support staff and
proactive delivery of software updates. For more information about this
service, please visit: http://www.hp.com/services/insight.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 6
QuickSpecs HP BladeSystem c7000 Enclosure
HP BladeSystem c-Class Overview
HP Matrix Operating The HP Matrix Operating Environment (Matrix OE) for ProLiant and Integrity
Environment servers is an integrated command center that helps you instantly adjust to
dynamic business demands. This advanced infrastructure management
software lets you reduce the cost of common data center tasks by up to 40
percent while keeping pace with your changing business.
The HP Matrix OE includes the automated provisioning, optimization, and
recovery management capabilities for HP CloudSystem Matrix, the ideal
platform for private cloud and Infrastructure as a Service (IaaS).
NOTE: For more information, visit: http://www.hp.com/go/matrixoe.
HP OneView Software The HP OneView architecture combines server, storage, and networking with control of datacenter
environmentals into a single, integrated management platform. Architected to deliver lifecycle
management for the complete Converged Infrastructure, it facilitates collaboration, removes friction,
collapses cycle times, eliminates error-prone work, and accelerates time to value. HP OneView
combines management of servers and virtual connect with open integration to automate and
customize existing tools and processes. With OneView, you'll work smarter-with greater visibility and
control-and fully capitalize on the benefits of a Converged Infrastructure.
For more information on HP OneView management, see: http://www.hp.com/go/oneview.
HP Power Advisor The HP Power Advisor is a tool provided by Hewlett-Packard to assist in the estimation of power
consumption and proper selection of components including power supplies at a system, rack, and
multi-rack level. A variety of additional features are also provided including a condensed bill of
materials, a cost of owner ship calculator, and a power report. The HP Power Advisor allows for the
mixing of rack, tower, blade, and other products in a single environment.
HP highly recommends using the HP Power Advisor tool to ensure the number of power supply options
you have selected can fully support your BladeSystem configuration and to review maximum system
power ratings for facilities planning purposes.
HP Power Advisor is available at: http://www.hp.com/go/hppoweradvisor.
Warranty Warranty - This product is covered by a global limited warranty and supported by HP Services and a
worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is
available for three years from date of purchase. Support for software and initial setup is available for
90 days from date of purchase. Additional support may be covered under the warranty or available for
an additional fee. Enhancements to warranty services are available through HP Care Pack services or
customized service agreements.
Enclosure: Three-year parts and labor, on-site limited global warranty. Certain restrictions
and exclusions apply
Enclosure options: Fans, power supplies, BladeSystem Onboard Administrator, 1 year parts
only or enclosure warranty
HP BladeSystem Interconnects: 1 year parts and labor, on-site regardless of the warranty
period for the system in which they are installed
HP Storage Fibre Channel switches have a maximum warranty period of one (1) year
regardless of the warranty period for the system in which they are installed
Hard drives have either a one year or three year warranty; refer to specific hard drive
QuickSpecs for details.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 7
QuickSpecs HP BladeSystem c7000 Enclosure
Service and Support
Service and Support HP Technology Services for Industry Standard Servers
HP Technology Services delivers confidence, reduces risk and helps customers realize agility and
stability. Connect to HP to help prevent problems and solve issues faster. Our support technology lets
you to tap into the knowledge of millions of devices and thousands of experts to stay informed and in
control, anywhere, any time.
Protect your business beyond warranty with HP Care Pack Services
HP Care Pack Services enable you to order the right service level, length of coverage and response time
as you purchase your new server, giving you full entitlement for the term you select.
Recommended HP Care Pack Services for your HP product
Optimized Care HP Proactive Care with 6 hour call-to-repair commitment, three year Care Pack Service
HP Proactive Care helps prevent problems and stabilize IT by utilizing secure, real-time, predictive
analytics and proactive consultations when your products are connected to HP. This Care Pack Service
combines three years’ proactive reporting and advice with our highest level reactive coverage and
enhanced escalation management, HP’s 24x7, six hour call-to-repair hardware commitment. HP is the
only leading manufacturer who makes this level of coverage available as a standard service offering
for your most valuable servers. Service includes 24x7 collaborative software support for leading
industry standard software running on your HP ProLiant server.
http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA3-8855ENW.pdf
Standard Care HP Proactive Care with 24x7 coverage, three year Care Pack Service
HP Proactive Care helps prevent problems and stabilize IT by utilizing secure, real-time, predictive
analytics and proactive consultations when your products are connected to HP. This Care Pack Service
combines three years’ proactive reporting and advice with our 24x7 coverage and enhanced escalation
management, four hour hardware response time and two hour call back for software questions on
leading industry standard software running on your HP ProLiant server.
http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA3-8855ENW.pdf
Related Services HP Installation and Startup Service for HP BladeSystem c-Class Infrastructure for c7000 enclosure
Provides for hardware installation (c-Class ProLiant and Integrity server blades, storage blades,
Ethernet Interconnects and Virtual Connect) and software installation and startup of a BladeSystem
c7000 Infrastructure in a single enclosure including deployment of OS (two servers), HP Insight Control
and Server Deployment (formerly RDP).
http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA0-5964ENW.pdf.
HP Installation and Startup Service for HP BladeSystem c-Class Enhanced Network
HP Provides for the configuration and testing of BladeSystem Ethernet interconnect switches and
Virtual Connect to facilitate proper implementation of network protocols and access to advanced
features.
http://h20195.www2.hp.com/V2/GetPDF.aspx/4aa0-5969ENW.pdf.
Recommended HP Care Pack Services for your HP Integrity product
Optimized Care 3- Year HP Critical Service
This service offers high performance reactive services and proactive components designed to minimize
planned and unplanned downtime. The key feature of this service is an assigned support team
including an Account Support Manager (ASM), Remote Support Account Advocate, Mission Critical
Hardware Specialist and access to HP's Global Mission Critical Solution Center to help resolve complex
issues faster. Reactive support components of this service include 24x7 HW and SW coverage, 6-hour
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 8
QuickSpecs HP BladeSystem c7000 Enclosure
Service and Support
Call-to-Repair commitment, enhanced parts inventory and accelerated escalation management.
http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA0-1613ENW.pdf.
HP Integrity C7000 Enclosure Startup Service
This service provides efficient and effective HP Integrity Blade infrastructure setup for the server
infrastructure including all hardware and networking components.
http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA1-1651ENW.pdf.
HP Installation and Startup Service for HP BladeSystem c-Class Enhanced Network
HP Provides for the configuration and testing of BladeSystem Ethernet interconnect switches and
Virtual Connect to facilitate proper implementation of network protocols and access to advanced
features.
http://h20195.www2.hp.com/V2/GetPDF.aspx/4aa0-5969ENW.pdf.
Standard Care 3-Year HP Proactive 24
This service offers improved stability, availability, and operational effectiveness through integrated
hardware and software support services that combine industry-leading reactive technical assistance
with proactive account services delivered by an ASM, giving you IT management support with a team of
service specialists. http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA0-1614ENW.pdf.
HP Integrity C7000 Enclosure Startup Service
This service provides efficient and effective HP Integrity Blade infrastructure setup for the server
infrastructure including all hardware and networking components.
http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA1-1651ENW.pdf.
HP Installation and Startup Service for HP BladeSystem c-Class Enhanced Network
HP Provides for the configuration and testing of BladeSystem Ethernet interconnect switches and
Virtual Connect to facilitate proper implementation of network protocols and access to advanced
features.
http://h20195.www2.hp.com/V2/GetPDF.aspx/4aa0-5969ENW.pdf.
Related Services HP Factory Express
When you add additional enclosures to your environment, consider HP Factory Express. HP Factory
Express provides customization and deployment services along with your storage and server
purchases. You can customize hardware to your exact specifications in the factory-helping speed
deployment.
http://hp.com/go/factoryexpress.
Get connected to HP to Connecting products to HP will help prevent problems with 24x7monitoring, prefailure alerts,
improve your support automatic call logging, and parts dispatch, plus current data will be available for the proactive reports
experience that are part of Proactive Care Services. With Connected products, you can have a dashboard to
manage your IT anywhere, anytime, from any device.
HP Support Center Personalized online support portal with access to information, tools and experts to support HP
business products. Submit support cases online, chat with HP experts, access support resources or
collaborate with peers. Learn more http://www.hp.com/go/hpsc.
HP's Support Center Mobile App allows you to resolve issues yourself or quickly connect to an agent for
live support. Now, you can get access to personalize IT support anywhere, anytime.
HP Insight Remote Support and HP Support Center are available at no additional cost with a HP
warranty, HP Care Pack or HP contractual support agreement.
NOTE: HP Support Center Mobile App is subject to local availability.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 9
QuickSpecs HP BladeSystem c7000 Enclosure
Service and Support
Parts and Materials HP will provide HP-supported replacement parts and materials necessary to maintain the
covered hardware product in operating condition, including parts and materials for available
and recommended engineering improvements.
Parts and components that have reached their maximum supported lifetime and/or the
maximum usage limitations as set forth in the manufacturer's operating manual, product
quick-specs, or the technical product data sheet will not be provided, repaired, or replaced as
part of these services.
The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives
replaced by HP due to malfunction.
For more information To learn more on HP ProLiant servers and HP BladeSystem servers, please contact your HP sales
representative or HP Authorized Channel Partner. Or visit:
www.hp.com/services/bladesystem.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 10
QuickSpecs HP BladeSystem c7000 Enclosure
Pre-configured Models
HP BladeSystem NOTE: HP does not allow factory integration of options into pre-configured models. Any additional
c-Class Server Blade options purchased will be shipped separately.
Enclosures NOTE: If you desire a custom configuration, please see the "Configuration Information - Factory
Integrated Models" section of this QuickSpecs.
NOTE: Each BladeSystem c7000 Enclosure holds up to 16 half-height server blades, 8 full-height
server blades, and/or 8 expansion blades per enclosure (not exceeding 16 total blades).
NOTE: HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen9 ProLiant and Integrity
server blades, subject to support requirements of the Onboard Administrator. If configuring an
enclosure with only Gen9 server blades, Onboard Administrator firmware 4.11 or greater is required.
If configuring an enclosure with a mix of Gen9 and earlier server blades, G6 to Gen9 is supported and
requires Onboard Administrator firmware 4.30 or greater. In addition to these requirements, the
Onboard Administrator firmware must be a version that supports all the components in the
enclosure. HP recommends the current firmware whenever possible for maximum compatibility and
stability. Updating the Onboard Administrator firmware may also require other subsystem firmware
upgrades. For further information, please see the HP Service Pack for ProLiant (SPP) website and the
HP Support Center documents “HP ProLiant Server Blades - Compatibility with HP BladeSystem
c7000 and c3000 Enclosures and Firmware” and ”ProLiant Gen9 Servers - Onboard Administrator
Firmware Version 4.11 (or Later) Support for Gen9 Server Blades and Possible Issues That May Arise”.
HP BLc7000 Platinum Enclosure with 1 Phase 6 Pwr Supplies 10 Fans ROHS 16 763850-B21
OneView Licenses
NOTE: The c7000 Platinum Enclosure 763850-B21 includes sixteen (16) HP
OneView licenses, six (6) 2400W Platinum hot-plug power supplies each with a
worldwide 250W C19 - C20 2.0m jumper cord, a single-phase 200-240V AC
Intelligent Power Module, ten (10) hot-plug Active Cool 200 Fans, an Onboard
Administrator with KVM, and the following blanking panels: 15 device bay, 7
interconnect module bay, and 1 redundant Onboard Administrator module bay.
HP BLc7000 Platinum Enclosure with 1 Phase 6 Power Supplies 10 Fans ROHS 16 681842-B21
Insight Control Licenses
NOTE: The c7000 Platinum Enclosure 681842-B21 includes sixteen (16) HP Insight
Control licenses, six (6) 2400W Platinum hot-plug power supplies each with a
worldwide 250W C19 - C20 2.0m jumper cord, a single-phase 200-240V AC
Intelligent Power Module, ten (10) hot-plug Active Cool 200 Fans, an Onboard
Administrator with KVM, and the following blanking panels: 15 device bay, 7
interconnect module bay, and 1 redundant Onboard Administrator module bay.
HP BLc7000 Platinum Enclosure w/ 1 Phase 2 Power Supplies 4 Fans ROHS Trial 681840-B21
Insight Control License
NOTE: The c7000 Platinum Enclosure 681840-B21 includes sixteen (16) HP Insight
Control trial licenses, two (2) 2400W Platinum hot-plug power supplies each with a
worldwide 250W C19 - C20 2.0m jumper cord, a single-phase 200-240V AC
Intelligent Power Module, four (4) hot-plug Active Cool 200 Fans, an Onboard
Administrator with KVM, and the following blanking panels: 15 device bay, 4 power
supply bay, 6 fan bay, 7 interconnect module bay, and 1 redundant Onboard
Administrator module bay.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 11
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
NOTE: This section lists some of the required and optional steps to configure a Factory Integrated Model. To ensure only valid
configurations are ordered, HP recommends contacting your local sales representative for information on Factory Integrated
Model product offerings and requirements.
For a configuration of the HP BladeSystem, please do the following:
Step 1: Select desired model, configuration, and quantity of HP ProLiant server and
expansion blades per enclosure (required)
NOTE: Each BladeSystem c7000 Enclosure holds up to 16 half-height server blades, 8 full-height server blades, and/or 8
expansion blades per enclosure (not exceeding 16 total blades).
NOTE: HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen9 ProLiant and Integrity server blades, subject to
support requirements of the Onboard Administrator. If configuring an enclosure with only Gen9 server blades, Onboard
Administrator firmware 4.11 or greater is required. If configuring an enclosure with a mix of Gen9 and earlier server blades, G6
to Gen9 is supported and requires Onboard Administrator firmware 4.30 or greater. In addition to these requirements, the
Onboard Administrator firmware must be a version that supports all the components in the enclosure. HP recommends the
current firmware whenever possible for maximum compatibility and stability. Updating the Onboard Administrator firmware
may also require other subsystem firmware upgrades. For further information, please see the HP Service Pack for ProLiant (SPP)
website and the HP Support Center documents “HP ProLiant Server Blades - Compatibility with HP BladeSystem c7000 and
c3000 Enclosures and Firmware” and ”ProLiant Gen9 Servers - Onboard Administrator Firmware Version 4.11 (or Later) Support
for Gen9 Server Blades and Possible Issues That May Arise”.
Step 2: Determine the HP BladeSystem c-Class Enclosure(s) and choose options (required)
(One of the following from each list unless otherwise noted)
Select the base server blade enclosure configuration (required)
HP BladeSystem NOTE: The enclosures listed below include an Onboard Administrator with KVM and four (4) hot-plug
BLc7000 c-Class Server Active Cool 200 Fans. The power module, power supply kits, power cables, interconnects, additional
Blade Enclosures fans, etc. are added per the steps below.
NOTE: The enclosures listed below include the required blanking panels (device bay, interconnect
module, fan, power, and redundant OA module) as required per the ordered configuration. If the
configuration is modified at a later date, additional blanking panels (ordered separately) may be
required.
HP BLc7000 Configure-to-order Platinum Enclosure with ROHS Trial Insight Control 681844-B21
License
HP Integrity BLc7000 CTO Enclosure AD361D
NOTE: The AD361D enclosure is suggested for configurations primarily used with
Integrity blades.
Select the enclosure power and cooling options (required)
HP c-Class Power c-Class Power Modules (1 per enclosure)
Systems HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21
NOTE: This power module is for single phase, high-line 200-240VAC applications and
has six blue IEC-320 C20 power connectors that accept IEC C19-C20 power cables.
NOTE: The blue power connectors indicate HP Power Discovery Services capability.
HP Power Discovery Services are enabled when used with a HP Power Discovery
Services-enabled power system including an Intelligent Power Distribution Unit
(iPDU), C19-C20 iPDU cables, and the Platinum power supply kits 733460-B21,
733459-B21, 517521-B21, or 588603-B21. See the iPDU, iPDU cable, c-Class Power
Supply sections below for these options.
NOTE: Also accepts standard (non-iPDU) C19 to C20 power cables, but HP Power
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 12
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
Discovery Services are disabled. One WW 250W C19-C20 2.0m (non-iPDU) cable is
included per supported power supply. Supported power supplies are listed here.
NOTE: This power module may be used with the power supply kits 733460-B21,
733459-B21, 517521-B21, 588603-B21, 517521-B21, or 499243-B21. See the "c-
Class Power Supply" section below for the power supply kits.
HP BLc7000 1 PH FIO Power Module Option 413379-B21
NOTE: This power module is for single phase, high-line 200-240VAC applications and
has six IEC-320 C20 power connectors that accept IEC C19-C20 power cables. One WW
250W C19-C20 2.0m (non-iPDU) cable is included per supported power supply.
Supported power supplies are listed here.
NOTE: This power module may be used with the power supply kits 733460-B21,
733459-B21, 517521-B21, 588603-B21, 517521-B21, or 499243-B21. See the "c-
Class Power Supply" section below for the power supply kits.
NOTE: This power module disables HP Power Discovery Services.
HP BLc7000 3 PH NA/JP FIO Power Module Option 413380-B21
NOTE: This power module is for three phase, high-line 200-208VAC North America
and Japan applications and has two 3.05m (10 ft) power cables with NEMA L15-30p
connectors.
NOTE: This power module may be used with the power supply kits 733460-B21,
733459-B21, 517521-B21, 588603-B21, 517521-B21, or 499243-B21. See the "c-
Class Power Supply" section below for the power supply kits.
NOTE: This power module disables HP Power Discovery Services.
NOTE: This power module requires a minimum of 3 power supply option kits. For full
redundancy, 6 power supply option kits are required.
HP BLc7000 -48V DC Power Input Module AH331A
NOTE: This power module is for -36VDC to -72VDC applications and has 45DG 4AWG
1/4 2H terminal lug connectors. It is used with the HP 2250W -48VDC Hot Plug Power
Supply Kit, AH332A. See the "c-Class Power Supply" section below for the power
supply kits.
NOTE: This power module disables HP Power Discovery Services.
HP HVDC 1PH AC Power Module BLc FIO Option 753623-B21
NOTE: This power module is for 277VAC and 380VDC applications and has six APP
Saf-D-Grid connectors. It is used with the HP 2650W Universal Hot Plug Power Supply
Kits (753618-B21 or 753619-B21). See the "c-Class Power Supply" section below for
the power supply kits.
NOTE: Cables are not included and may be ordered separately; see cable options
J6X01A, J6X02A, J6X03A (277VAC applications) and J6W98A, J6W99A, J6X00A
(277VAC or 380VDC applications).
NOTE: This power module disables HP Power Discovery Services.
c-Class Power Supply (Up to 6)
NOTE: HP highly recommends using the HP Power Advisor tool to ensure the number
of power supply options you have selected can fully support your BladeSystem
configuration and to review maximum system power ratings for facilities planning
purposes. HP Power Advisor is available at: http://www.hp.com/go/hppoweradvisor.
NOTE: Each enclosure must include only one type of power supply. Mixing of power
supplies is not supported, except during hot swaps to different level or higher
efficient power supplies. The Onboard Administrator will exhibit a mismatch error due
to mixed power supplies until all power supplies are matched.
NOTE: If a three phase power module is selected (413380-B21), a minimum of 3
power supply option kits is required. For full redundancy, 6 power supply option kits
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 13
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
are required.
NOTE: HP c7000 enclosure AC power supplies meet 80 PLUS Platinum or Gold power
efficiency requirements: Platinum (94%) and Gold (92%). The 80 PLUS program is a
unique forum that unites electric utilities, the computer industry, and consumers in
an effort to bring energy efficient technology solutions to the marketplace. 80 PLUS
independently tests power supply efficiency and publically posts the results on
80Plus.org. DC power supplies are not eligible for 80 PLUS testing; efficiency is per HP
internal testing.
HP 6X 2650W Platinum Hot Plug FIO Power Supply Kit 733460-B21
NOTE: This power supply kit enables HP Power Discovery Services when used with the
HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21. See the "c-Class
Power Modules" section above for the power modules.
NOTE: Includes a quantity of 6 HP 2650W Platinum 94% power supplies so a full
enclosure can be configured with a single part number.
NOTE: Includes six WW 250W C19 - C20 2.0m Jumper Cords.
NOTE: This power supply kit meets multiple energy efficiency initiatives: 2650W,
94%: Climate Savers Computing Initiative PLATINUM and ECOS Consulting 80 PLUS
Platinum.
HP 2650W Platinum Hot Plug Power Supply Kit 733459-B21
NOTE: This power supply kit enables HP Power Discovery Services when used with the
HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21. See the "c-Class
Power Modules" section above for the power modules.
NOTE: Includes one WW 250W C19 - C20 2.0m Jumper Cord.
NOTE: This power supply kit meets multiple energy efficiency initiatives: 2650W,
94%: Climate Savers Computing Initiative PLATINUM and ECOS Consulting 80 PLUS
Platinum.
HP 6X 2400W Platinum Hot Plug Factory Integrated Power Supply Kit 517521-B22
NOTE: This power supply kit enables HP Power Discovery Services when used with the
HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21. See the "c-Class
Power Modules" section above for the power modules.
NOTE: Includes a quantity of 6 HP 2400W Platinum 94% efficient power supplies so a
full enclosure can be configured with a single part number.
NOTE: Includes six WW 250W C19 - C20 2.0m Jumper Cords.
NOTE: This power supply kit meets multiple energy efficiency initiatives: 2400W,
94%: Climate Savers Computing Initiative PLATINUM and ECOS Consulting 80 PLUS
Platinum.
HP 2400W Platinum Hot Plug Power Supply Kit 588603-B21
NOTE: This power supply kit enables HP Power Discovery Services when used with the
HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21. See the "c-Class
Power Modules" section above for the power modules.
NOTE: Includes one WW 250W C19 - C20 2.0m Jumper Cord.
NOTE: This power supply kit meets multiple energy efficiency initiatives: 2400W,
94%: Climate Savers Computing Initiative PLATINUM and ECOS Consulting 80 PLUS
Platinum.
HP 6X 2400W Gold Hot Plug Factory Integrated Power Supply Kit 517521-B21
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Includes six WW 250W C19 - C20 2.0m Jumper Cords.
NOTE: Includes a quantity of 6 HP 2400W Gold 92% efficient power supplies so a full
enclosure can be configured with a single part number.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 14
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
HP 2400W Gold Hot Plug Power Supply Kit 499243-B21
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Includes one WW 250W C19 - C20 2.0m Jumper Cord.
HP 2250W -48VDC Hot Plug Power Supply Kit AH332A
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Compatible with the HP BLc7000 -48V DC Power Input Module AH331A. See the
"c-Class Power Modules" section above for the power modules.
HP 2650W Universal Hot Plug Power Supply Kit 753618-B21
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Compatible with the HP HVDC 1PH AC Power Module BLc FIO Option 753623-
B21. See the "c-Class Power Modules" section above for the power modules.
NOTE: Cables are not included and may be ordered separately; see cable options
J6X01A, J6X02A, J6X03A (277VAC applications) and J6W98A, J6W99A, J6X00A
(277VAC or 380VDC applications).
HP 6X 2650W Universal Hot Plug Power Supply Kit 753619-B21
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Compatible with the HP HVDC 1PH AC Power Module BLc FIO Option 753623-
B21. See the "c-Class Power Modules" section above for the power modules.
NOTE: Cables are not included and may be ordered separately; see cable options
J6X01A, J6X02A, J6X03A (277VAC applications) and J6W98A, J6W99A, J6X00A
(277VAC or 380VDC applications).
NOTE: Includes a quantity of 6 2650W universal power supplies so a full enclosure
can be configured with a single part number.
HP Cooling Options c-Class Active Cool 200 Fan (Up to 6)
NOTE: A minimum of 4 Active Cool 200 Fans is required to a maximum of 10 Active Cool 200 Fans.
The enclosure selected in Step 2 already includes 4 fans allowing up to 6 additional.
NOTE: Ten Active Cool 200 Fans are strongly recommended for maximum cooling efficiency and
redundancy, reduced power consumption, and reduced noise.
NOTE: Enclosures configured with a three-phase power input module require a minimum of 6 Active
Cool 200 Fans.
NOTE: Some blade configurations require 10 Active Cool 200 Fans.
NOTE: For the complete list of fan requirements and recommendations, see the “Server Blade and
Fan Population Guidelines” section of this document.
HP BLc 6X Active Cool 200 Factory Integrated Fan Option 517520-B21
NOTE: This option (517520-B21) includes a quantity of 6 HP Active Cool 200 Fans so a
full enclosure can be configured with 10 fans using a single part number.
HP BLc7000 Enclosure HP Single Active Cool Fan Option Kit 412140-B21
Step 3: Select a software bundle (optional) or Insight Sofware (Factory Integratable Only)
(if nothing is selected the enclosure will ship with 16 Insight Control Trial Licenses)
HP OneView Software HP OneView incl 3yr 24x7 Supp Enclosure Bundle 16 Svr E-LTU E5Y41AAE
NOTE: Server provisioning capability (i.e. 'Insight Control server provisioning') is
included and licensed as part of HP OneView. This capability is ideal for multi-server
OS and driver provisioning to ProLiant and BladeSystem servers. A media kit ("HP
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 15
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
Insight Control server provisioning USB media kit", BD883A), which includes a USB
flash drive, is available for customers who require a physical copy of the software on
media. This media kit is separate and in addition to the "HP OneView Media Kit",
E5Y37A.
NOTE: HP OneView licenses ship without media. The HP OneView Media Kit can be
ordered separately (part number E5Y37A), or can be downloaded at:
http://www.hp.com/go/oneview.
HP Insight Software NOTE: The Insight Control licenses listed below support HP ProLiant c-Class server
blades.
NOTE: Licenses ship without media. The Insight Management Media Kit can be
ordered separately, or can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Customer will receive a license entitlement certificate, which must be
redeemed online or via fax in order to obtain the license activation key(s). Includes
one year of 24 x 7 HP Software Technical Support Service.
NOTE: For additional license kits, please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html.
HP Insight Control for BladeSystem including 1yr 24x7 Support Enclosure 16 Svr FIO C6N33ABE
Electronic License
HP Insight Control for BladeSystem including 1yr 24x7 Support Enclosure 8 Svr FIO C6N32ABE
Electronic License
Step 4: Select a redundant BladeSystem Onboard Administrator (optional)
HP c-Class Enclosure HP BLc7000 Onboard Administrator with KVM Option 456204-B21
Options NOTE: The HP c7000 Onboard Administrator (OA) supports the mixing with the HP
c7000 OA with KVM. The HP c7000 OA with KVM must be the active OA to provide the
enclosure KVM feature. The KVM menu has an OA CLI button at the bottom, which
allows an OA administrator to log into the OA and be able to force a takeover so the
OA with KVM will become the standby OA. The OA Firmware Sync feature cannot be
used to update mismatched OA modules. Mismatched OA firmware versions between
the original c7000 OA and c7000 OA with KVM require the administrator to use the
GUI or CLI to update the OA from a file (http, ftp, tftp, local client file using the GUI or
USB key containing the OA firmware file).
NOTE: The c7000 enclosure (part numbers 681840-B21, 681842-B21, 681844-B21,
763850-B21, and AD361D) come with a BladeSystem Onboard Administrator with
KVM as standard. Order this part number (456204-B21) when a second redundant
BladeSystem Onboard Administrator is desired for a c7000 enclosure.
NOTE: HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen9
ProLiant and Integrity server blades in the same enclosure.
HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen 9 ProLiant and
Integrity server blades, subject to support requirements of the Onboard
Administrator. If configuring an enclosure with only Gen9 server blades, Onboard
Administrator firmware 4.11 or greater is required. If configuring an enclosure with a
mix of Gen9 and earlier server blades, G6 to Gen9 is supported and requires Onboard
Administrator firmware 4.30 or greater. In addition to these requirements, the
Onboard Administrator firmware must be a version that supports all the components
in the enclosure. HP recommends the current firmware whenever possible for
maximum compatibility and stability. Updating the Onboard Administrator firmware
may also require other subsystem firmware upgrades. For further information,
please see the HP Service Pack for ProLiant (SPP) website and the HP Support Center
documents “HP ProLiant Server Blades - Compatibility with HP BladeSystem c7000
and c3000 Enclosures and Firmware” and ”ProLiant Gen9 Servers - Onboard
Administrator Firmware Version 4.11 (or Later) Support for Gen9 Server Blades and
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 16
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
Possible Issues That May Arise”.
Step 5: Select 1 or more interconnect modules for each enclosure (required)
The following is a list of various HP BladeSystem c-Class interconnect modules (Virtual Connect, Ethernet, Fibre Channel,
InfiniBand, and SAS interconnects). A pair of interconnects must be ordered if redundancy is required. For detailed interconnect
options, consult the specific interconnect QuickSpecs: http://h18004.www1.hp.com/products/blades/components/c-class-
interconnects.html.
NOTE: Interconnect bays 1 and 2 support the network (i.e. Ethernet capable) interconnects. These bays connect to the included
network adapter ports in the server blades (either embedded ports on G7 and earlier server blades or FlexibleLOM adapter(s) on
Gen8 and later server blades) via the NonStop passive midplane. An enclosure must be configured with at least a network
interconnect in interconnect bay 1.
NOTE: Interconnect bays 3 through 8 support all interconnects. These bays connect to the mezzanine slots in the server blades
via the NonStop passive midplane. Interconnect bays 3 and 4 must contain the same type of interconnect (network, SAN, SAS,
etc) as they connect to the same mezzanine slot. Likewise for interconnect bays 5, 6, 7, and 8.
NOTE: The HP BladeSystem c-Class interconnects ship as single units unless otherwise noted. Interconnects must be ordered in
quantities of two for redundancy support.
NOTE: Options to specific c-Class interconnects are not included in the list below. Consult the individual interconnect QuickSpecs
to obtain part numbers for interconnect options such as cables, SFPs, etc.
HP BladeSystem HP Virtual Connect FlexFabric-20/40 F8 Module for c-Class BladeSystem 691367-B21
c-Class Network NOTE: Virtual Connect FlexFabric-20/40 F8 modules are supported on c7000
Interconnects enclosures with the following SKUs: 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
NOTE: A c7000 enclosure with a 10 fan configuration is required when one or more HP
Virtual Connect FlexFabric-20/40 F8 module(s) are installed.
HP Virtual Connect FlexFabric-20/40 F8 Module for c-Class BladeSystem with TAA 691367-B22
NOTE: Virtual Connect FlexFabric-20/40 F8 modules are supported on c7000
enclosures with the following SKUs: 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
NOTE: A c7000 enclosure with a 10 fan configuration is required when one or more HP
Virtual Connect FlexFabric-20/40 F8 module(s) are installed.
HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 Option 662048-B21
NOTE: 662048-B21 includes 2 x HP Virtual Connect Flex-10/10D modules plus 1 x
VCEM enclosure license. Customer will receive a printed license entitlement
certificate and 2 Virtual Connect modules as a single deliverable. The license
entitlement certificate must be redeemed online or via fax to obtain the VCEM license
activation key.
HP Virtual Connect Flex-10/10D Module for c-Class BladeSystem 638526-B21
HP Virtual Connect FlexFabric 10/24 Enterprise Edition BLc7000 Option 605865-B21
NOTE: 605865-B21 includes 2 x HP Virtual Connect FlexFabric 10Gb/24-port modules
plus 1 x VCEM BL-c7000 enclosure license. Customer will receive a printed license
entitlement certificate and 2 Virtual Connect modules as a single deliverable. The
license entitlement certificate must be redeemed online or via fax to obtain the VCEM
license activation key.
HP Virtual Connect FlexFabric 10Gb/24-port Module for c-Class BladeSystem 571956-B21
HP 6125G Ethernet Blade Switch 658247-B21
HP 6125G/XG Ethernet Blade Switch 658250-B21
HP 6120XG Blade Switch 516733-B21
HP 1GB Ethernet Pass-Thru Module for c-Class BladeSystem 406740-B21
HP 10GbE Ethernet Pass-Thru Module for c-Class BladeSystem 538113-B21
Mellanox SX1018HP Ethernet Switch for c-Class BladeSystem 689638-B21
Cisco Catalyst 1/10GbE 3120X Blade Switch 451439-B21
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 17
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
Cisco Catalyst 1GbE 3120G Blade Switch 451438-B21
HP Cisco B22HP Fabric Extender for BladeSystem c-Class 641146-B21
HP Cisco B22HP Fabric Extender with 16 FET for BladeSystem c-Class 657787-B21
NOTE: 657787-B21 includes 16 Cisco Fabric Extender Transceivers. These
transceivers can be used to connect the Fabric Extender with a parent Nexus 5000
over optical cable up to 100 meters using OM3 grade fiber.
HP SAS Switch NOTE: The HP 6Gb SAS switches are supported on c7000 enclosures with the following SKUs:
5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
HP 6Gb SAS Switch Single Pack for HP BladeSystem c-Class BK763A
HP 6Gb SAS Switch Dual Pack for HP BladeSystem c-Class BK764A
HP BladeSystem NOTE: HP Fibre Channel interconnect switches and modules supporting up to a 4Gbps internal port
c-Class SAN downlink speed (connection speed from the server blades to the interconnect) (SKU 403626-B21) are
Interconnects supported on all c7000 enclosures.
NOTE: HP Fibre Channel interconnect switches and modules supporting up to an 8Gbps internal port
downlink speed (connection speed from the server blades to the interconnect) (SKUs 466482-B21,
572018-B21, AJ820B, AJ821B, AJ822B, AW563A, and AW564A) are supported on all c7000
enclosures.
NOTE: HP Fibre Channel interconnect switches and modules supporting up to a 16Gbps internal port
downlink speed (connection speed from the server blades to the interconnect) (SKUs C8S45A,
C8S46A, C8S47A, 751465-B21, and 778720-B21) are supported on c7000 enclosures with the
following SKUs: 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21. A c7000 Platinum enclosure (SKUs
6XXXXX-B21 and 7XXXXX-B21) is required to permit the 16Gbps speed on the internal downlink
ports. A c7000 enclosure with SKU 5XXXXX-B21 will operate the internal ports up to 8Gbps.
HP Virtual Connect 16Gb 24-port Fibre Channel Module for c-Class BladeSystem 751465-B21
HP Virtual Connect 16Gb 24-port Fibre Channel TAA Module for c-Class BladeSystem 778720-B21
HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 466482-B21
HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 572018-B21
HP 4GB Fibre Channel Pass-thru Module for c-Class BladeSystem 403626-B21
Brocade 8/12c SAN Switch for BladeSystem c-Class AJ820B
Brocade 8/24c SAN Switch for BladeSystem c-Class AJ821B
Brocade 8/24c Power Pack+ SAN Switch for BladeSystem c-Class AJ822B
Cisco MDS 8/12c Fabric Switch for HP BladeSystem c-Class AW563A
Cisco MDS 8/24c Fabric Switch for HP BladeSystem c-Class AW564A
Brocade 16Gb/28 SAN Switch for BladeSystem c-Class C8S46A
Brocade 16Gb/16 SAN Switch for BladeSystem c-Class C8S45A
Brocade 16Gb/28 SAN Switch Power Pack+ for BladeSystem c-Class C8S47A
Brocade 8/16Gb Embedded FC Switch 12-port Upgrade LTU T5517A
HP BladeSystem NOTE: The HP QDR InfiniBand Switches are supported on c7000 enclosures with the following SKUs:
InfiniBand 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
Interconnects NOTE: The HP FDR InfiniBand Switches are supported on c7000 enclosures with the following SKUs:
686610-B21, 686611-B21, and 7XXXXX-B21.
HP 4X QDR QLogic InfiniBand Switch Module for c-Class BladeSystem 505958-B21
QLogic InfiniBand 4X QDR Management Module for c-Class BladeSystem 505959-B21
HP 4X QDR InfiniBand Switch Module for c-Class BladeSystem 489184-B21
HP 4X FDR InfiniBand Managed Switch Module for c-Class BladeSystem 648311-B21
HP 4X FDR InfiniBand Switch Module for c-Class BladeSystem 648312-B21
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 18
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
Step 6: Select rack (optional)
NOTE: Additional HP Data Center racks are available than those listed below. For information on the full line of HP Data Center
Racks and rack accessories, please see http://www.hp.com/go/rackandpower.
HP Data Center Racks HP 11000 G2 Series Racks
HP 11642 1075mm Shock Rack H6J66A
HP 11642 1200mm Shock Universal Rack H6J68A
HP 11648 1075mm Shock Rack H6J88A
HP 11842 1200mm Shock Rack H6J70A
HP Intelligent Series Rack
HP 636 1075mm Shock Intelligent Rack BW896A
HP 642 1075mm Shock Intelligent Rack BW904A
HP 647 1075mm Shock Intelligent Rack BW912A
HP Location Discovery Services
NOTE: For information on HP Location Discovery Services, please see
http://www.hp.com/go/rackandpower.
HP 47U Location Discovery Kit BW947A
HP 42U Location Discovery Kit BW946A
HP 36U Location Discovery Kit BW945A
Step 7: Select rack power distribution unit (PDU) (optional)
NOTE: A pair of PDUs must be ordered for AC feed redundancy.
NOTE: Additional HP Power Distribution Units (PDUs) are available than those listed below. For a complete list of all HP PDUs,
please visit: http://www.hp.com/go/rackandpower.
HP Power Distribution HP Basic Power Distribution Units (bPDUs)
Units (PDUs) HP 4.9kVA 208 Volt L6-30 Input (24xC13/6xC19) NA/JP Basic PDU H5M59A
HP 8.6kVA 208 Volt L15-30 3-Phase Input (24xC13/6xC19) NA/JP Basic PDU H5M62A
HP 8.6kVA 208 Volt L21-30 3-Phase Input (24xC13/3xC19/3xNEMA 5-20R) NA/JP Basic H5M64A
PDU
HP Remote Monitoring Power Distribution Units (mPDUs)
HP 4.9kVA 208 Volt L6-30 Input (20xC13/4xC19) NA/JP Monitored PDU D9N47A
HP 8.6kVA 208 Volt L15-30 3-Phase Input (18xC13/3xC19) NA/JP Monitored PDU D9N51A
HP 8.6kVA 208 Volt L21-30 3-Phase Input (20xC13/3xC19/3xNEMA 5-20R) NA/JP D9N53A
Monitored PDU
HP 14.4kVA 208 Volt CS8365C 3-Phase Input (12xC13/12xC19) NA Monitored PDU D9N58A
HP 16.6kVA 400 Volt IEC309 30A 3-Phase Input (12xC13/12xC19) NA Monitored PDU D9N62A
HP 17.3kVA 208 Volt IEC309 60A 3-Phase Input (24xC13/3xC19) NA/JP Monitored PDU D9N54A
HP 17.3kVA 208 Volt IEC309 60A 3-Phase Input (12xC13/12xC19) NA/JP Monitored D9N59A
PDU
HP 17.3kVA 208 Volt IEC309 60A 3-Phase Watertight Input (12xC13/12xC19) NA/JP G9Z07A
Monitored PDU
HP Environmental Sensor for Remote Monitored PDUs E2D53A
NOTE: The HP Environmental Sensor collects temperature and humidity information in
the rack and can be monitored via the local LCD display or remotely using Telnet or a
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 19
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
standard web interface. The sensor can also monitor the status of two user supplied
contact devices.
HP Intelligent Power Distribution Units (iPDUs)
HP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit AF520A
HP 8.6kVA 24A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit AF522A
HP 17.3kVA 48A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit AF523A
HP 17.3kVA 48A 208V Three Phase 12 Outlet Core NA/JP Intelligent Power Distribution AF535A
Unit
HP 17.3kVA 24A 415V Three Phase 12 Outlet Core NA/JP Intelligent Power Distribution AF537A
Unit
Step 8: Select an uninterruptible power system (UPS) (optional)
NOTE: Additional HP Uninterruptable Power Systems (UPSs) are available than those listed here. For a complete list of all HP
UPSs and additional information, please visit http://www.hp.com/go/rackandpower.
HP Uninterruptible R5000 Uninterruptible Power System (UPS)
Power Systems (UPSs) HP R5KVA 3U L630 High Voltage NA/JP Uninterruptible Power System AF460A
R7000 Uninterruptible Power System (UPS)
HP R7KVA 4U 50A High Voltage NA/JP Uninterruptible Power System AF462A
HP R8000/3 Uninterruptible Power System (UPS)
HP R8000/3 8000kVA Three Phase NA 6U Rackmount Uninterruptible Power System AF431A
HP R12000/3 Uninterruptible Power System (UPS)
HP R12000/3 12000VA Three Phase NA 6U Rackmount Uninterruptible Power System AF429A
Step 9: Select power cords (optional)
NOTE: For additional power cable information, please visit:
http://h18000.www1.hp.com/products/servers/proliantstorage/power-protection/options/power-cable.html.
HP Intelligent Power NOTE: Order with HP Single Phase FIO Intelligent Power Module for c-Class BladeSystem (677595-
Distribution Units B21). These power cables enable Power Discovery Services communications between the HP
Power cords BladeSystem c7000 Enclosure and HP Intelligent PDUs.
NOTE: These power cables are designated by bright blue IEC connectors.
(HP C19 to C20)
HP 1.37m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK744A
HP 1.37m 250V 16A C19-C20 WW 3PC Kit IPD Enabled Jumper Cord TK745A
HP 2.0m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK738A
HP 2.0m 250V 16A C19-C20 WW 3PC Kit IPD Enabled Jumper Cord TK739A
HP 2.5m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK740A
HP 2.5m 250V 16A C19-C20 WW 3PC Kit IPD Enabled Jumper Cord TK741A
HP 3.0m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK742A
HP 3.0m 250V 16A C19-C20 WW 3PC Kit IPD Enabled Jumper Cord TK743A
HP Power Distribution HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord AF575A
Units Power cords HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord AF574A
(HP C19 to C20)
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord 295633-B22
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 20
QuickSpecs HP BladeSystem c7000 Enclosure
Configuration Information Factory Integrated Models
HP C19 - C20 WW 250V 16Amp 4.5m Jumper Cord E7804A
Additional HP power HP High Line Power Cords 200 - 240V AC
Cords HP C19 -Nema L6-30P US/CA 250V 16Amp 4.5m Power Cord E7805A
HP C19 - Nema L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord AF593A
HP High Voltage Power Cords 277V AC, 380V DC
NOTE: Power cables J6W98A, J6W99A, and J6X00A are intended for 277VAC or 380VDC
APP Saf-D-Grid to APP Saf-D-Grid applications.
NOTE: Power cables J6X01A, J6X02A, and J6X03A are intended for 277VAC APP Saf-D-
Grid to LS-25 applications.
HP SDGRD-SDGRD 380V 15A DC 0.76m Jpr Crd J6W98A
HP SDGRD-SDGRD 380V 15A DC 1.37m Jpr Crd J6W99A
HP SDGRD-SDGRD 380V 15A DC 2.0m Jpr Crd J6X00A
HP SDGRD-LS25 277V 15A AC 0.76m Jpr Crd J6X01A
HP SDGRD-LS25 277V 15A AC 1.37m Jpr Crd J6X02A
HP SDGRD-LS25 277V 15A AC 2.0m Jpr Crd J6X03A
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 21
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
HP Enclosure Options HP BLc7000 Onboard Administrator with KVM Option 456204-B21
NOTE: The HP c7000 Onboard Administrator (OA) supports the mixing with the HP
c7000 OA with KVM. The HP c7000 OA with KVM must be the active OA to provide the
enclosure KVM feature. The KVM menu has an OA CLI button at the bottom, which
allows an OA administrator to log into the OA and be able to force a takeover so the
OA with KVM will become the standby OA. The OA Firmware Sync feature cannot be
used to update mismatched OA modules. Mismatched OA firmware versions between
the original c7000 OA and c7000 OA with KVM require the administrator to use the
GUI or CLI to update the OA from a file (http, ftp, tftp, local client file using the GUI or
USB key containing the OA firmware file).
NOTE: The c7000 enclosure (part numbers 681840-B21, 681842-B21, 681844-B21,
763850-B21, and AD361D) come with a BladeSystem Onboard Administrator with
KVM as standard. Order this part number (456204-B21) when a second redundant
BladeSystem Onboard Administrator is desired for a c7000 enclosure.
NOTE: HP BladeSystem c3000 and c7000 Enclosures support G1 through Gen9
ProLiant and Integrity server blades, subject to support requirements of the Onboard
Administrator. Certain HP ProLiant server blades and options may require a specific
version of the Onboard Administrator firmware. This firmware release may also
require other subsystem firmware upgrades. For further information, please see the
HP Service Pack for ProLiant (SPP) website and the HP Support Center document “HP
ProLiant Server Blades - Compatibility with HP BladeSystem c7000 and c3000
Enclosures and Firmware”.
HP BLc7000 10000 Series Rack Shipping Bracket Option 433718-B21
NOTE: The shipping bracket is required when shipping a c7000 enclosure when
installed in a rack. It is not required for normal operation.
HP c-Class BladeSystem Miscellaneous Blanks Option Kit 412148-B21
NOTE: Contains 1 each of c3000/c7000 Active Cool Fan blank, c3000/c7000
interconnect module blank, c7000 Onboard Administrator blank, c3000 local KVM
blank, c3000 power supply blank, c7000 power supply blank, c3000 DVD blank, and a
c3000 mini-divider.
NOTE: This kit is designed to replace lost or damaged blanks, or if reconfiguring an
enclosure where additional blanks are required.
HP c-Class BladeSystem Bay Blank with Coupler Option 412150-B21
NOTE: This is option contains one half-height device blank and a coupler that can be
used for the c3000 and c7000 enclosures.
NOTE: Order quantity of one 412150-B21 for filling a half-height bay; the coupler is
not used.
NOTE: Order quantity of two 412150-B21 for filling a full-height bay. One coupler is
installed between the two half-height blanks to be connected together to create a
full-height blank.
NOTE: This kit is designed to replace lost or damaged blanks, or if reconfiguring an
enclosure where additional blanks are required.
HP Power Supplies NOTE: HP highly recommends using the HP Power Advisor tool to ensure the number
of power supply options you have selected can fully support your BladeSystem
configuration and to review maximum system power ratings for facilities planning
purposes. HP Power Advisor is available at: http://www.hp.com/go/hppoweradvisor.
NOTE: Mixing of power supplies is not supported on BladeSystem c7000 Enclosures,
except during hot swaps to different level power supplies. The Onboard
Administrator will exhibit a mismatch error due to mixed power supplies until all
power supplies are matched.
NOTE: If a three phase power module is selected (413380-B21), a minimum of 3
power supply option kits are required. For full redundancy, 6 power supply option kits
are required.
NOTE: HP c7000 enclosure AC power supplies meet 80 PLUS Platinum or Gold power
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 22
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
efficiency requirements: Platinum (94%) and Gold (92%). The 80 PLUS program is a
unique forum that unites electric utilities, the computer industry, and consumers in
an effort to bring energy efficient technology solutions to the marketplace. 80 PLUS
independently tests power supply efficiency and publically posts the results on
80Plus.org. DC power supplies are not eligible for 80 PLUS testing; efficiency is per HP
internal testing.
HP 2650W Platinum Hot Plug Power Supply Kit 733459-B21
NOTE: This power supply kit enables HP Power Discovery Services when used with the
HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21. See the "c-Class
Power Modules" section above for the power modules.
NOTE: Includes one WW 250W C19 - C20 2.0m Jumper Cord.
NOTE: This power supply kit meets multiple energy efficiency initiatives: 2650W,
94%: Climate Savers Computing Initiative PLATINUM and ECOS Consulting 80 PLUS
Platinum.
HP 2400W Platinum Hot Plug Power Supply Kit 588603-B21
NOTE: This power supply kit enables HP Power Discovery Services when used with the
HP BLc7000 Single Phase FIO Intelligent Power Module 677595-B21. See the "c-Class
Power Modules" section above for the power modules.
NOTE: Includes one WW 250W C19 - C20 2.0m Jumper Cord.
NOTE: This power supply kit meets multiple energy efficiency initiatives: 2400W,
94%: Climate Savers Computing Initiative PLATINUM and ECOS Consulting 80 PLUS
Platinum.
HP 2400W Gold Hot Plug Power Supply Kit 499243-B21
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Includes one WW 250W C19 - C20 2.0m Jumper Cord.
HP 2250W -48VDC Hot Plug Power Supply Kit AH332A
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Only compatible with the HP BLc7000 -48V DC Power Input Module AH331A.
See the "c-Class Power Modules" section above for the power modules.
HP 2650W Universal Hot Plug Power Supply Kit 753618-B21
NOTE: This power supply kit disables HP Power Discovery Services.
NOTE: Compatible with the HP HVDC 1PH AC Power Module BLc FIO Option 753623-
B21. See the "c-Class Power Modules" section above for the power modules.
NOTE: Cables are not included and may be ordered separately; see cable options
J6X01A, J6X02A, J6X03A (277VAC applications) and J6W98A, J6W99A, J6X00A
(277VAC or 380VDC applications).
HP Cooling Options HP c-Class Active Cool Fan
HP BLc7000 Enclosure HP Single Active Cool Fan Option Kit 412140-B21
NOTE: A minimum of 4 Active Cool 200 Fans is required to a maximum of 10 Active
Cool 200 Fans.
NOTE: Ten Active Cool 200 Fans are strongly recommended for maximum cooling
efficiency and redundancy, reduced power consumption, and reduced noise.
NOTE: Enclosures configured with a three-phase power input module require a
minimum of 6 Active Cool 200 Fans.
NOTE: Some blade configurations require 10 Active Cool 200 Fans.
NOTE: For the complete list of fan requirements and recommendations, see the
“Server Blade and Fan Population Guidelines” section of this document.
HP BladeSystem NOTE: For detailed interconnect options, consult the specific interconnect QuickSpecs:
c-Class Network http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html.
Interconnects NOTE: Interconnect bays 1 and 2 support the network (i.e. Ethernet capable) interconnects. These
bays connect to the included network adapter ports in the server blades (either embedded ports on
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 23
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
G7 and earlier server blades or FlexibleLOM adapter(s) on Gen8 and later server blades) via the
NonStop passive midplane. An enclosure must be configured with at least a network interconnect in
interconnect bay 1.
NOTE: Interconnect bays 3 through 8 support all interconnects. These bays connect to the mezzanine
slots in the server blades via the NonStop passive midplane. Interconnect bays 3 and 4 must contain
the same type of interconnect (network, SAN, SAS, etc) as they connect to the same mezzanine slot.
Likewise for interconnect bays 5, 6, 7, and 8.
NOTE: The HP BladeSystem c-Class interconnects ship as single units unless otherwise noted.
Interconnects must be ordered in quantities of two for redundancy support.
NOTE: Options to specific c-Class interconnects are not included in the list below. Consult the
individual interconnect QuickSpecs to obtain part numbers for interconnect options such as cables,
SFPs, etc.
HP Virtual Connect FlexFabric-20/40 F8 Module for c-Class BladeSystem 691367-B21
NOTE: Virtual Connect FlexFabric-20/40 F8 modules are supported on c7000
enclosures with the following SKUs: 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
NOTE: A c7000 enclosure with a 10 fan configuration is required when one or more HP
Virtual Connect FlexFabric-20/40 F8 Module(s) are installed.
HP Virtual Connect FlexFabric-20/40 F8 Module for c-Class BladeSystem with TAA 691367-B22
NOTE: Virtual Connect FlexFabric-20/40 F8 modules are supported on c7000
enclosures with the following SKUs: 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
NOTE: A c7000 enclosure with a 10 fan configuration is required when one or more HP
Virtual Connect FlexFabric-20/40 F8 Module(s) are installed.
HP Virtual Connect Flex-10/10D Module Enterprise Edition for BLc7000 Option 662048-B21
NOTE: 662048-B21 includes 2 x HP Virtual Connect Flex-10/10D modules plus 1 x
VCEM enclosure license. Customer will receive a printed license entitlement
certificate and 2 Virtual Connect modules as a single deliverable. The license
entitlement certificate must be redeemed online or via fax to obtain the VCEM license
activation key.
HP Virtual Connect Flex-10/10D Module for c-Class BladeSystem 638526-B21
HP Virtual Connect FlexFabric 10/24 Enterprise Edition BLc7000 Option 605865-B21
NOTE: 605865-B21 includes 2 x HP Virtual Connect FlexFabric 10Gb/24-port modules
plus 1 x VCEM BL-c7000 enclosure license. Customer will receive a printed license
entitlement certificate and 2 Virtual Connect modules as a single deliverable. The
license entitlement certificate must be redeemed online or via fax to obtain the VCEM
license activation key.
HP Virtual Connect FlexFabric 10Gb/24-port Module for c-Class BladeSystem 571956-B21
HP 6125G Ethernet Blade Switch 658247-B21
HP 6125G/XG Ethernet Blade Switch 658250-B21
HP 6120XG Blade Switch 516733-B21
HP 1GB Ethernet Pass-Thru Module for c-Class BladeSystem 406740-B21
HP 10GbE Ethernet Pass-Thru Module for c-Class BladeSystem 538113-B21
Mellanox SX1018HP Ethernet Switch for c-Class BladeSystem 689638-B21
Cisco Catalyst 1/10GbE 3120X Blade Switch 451439-B21
Cisco Catalyst 1GbE 3120G Blade Switch 451438-B21
HP Cisco B22HP Fabric Extender for BladeSystem c-Class 641146-B21
HP Cisco B22HP Fabric Extender with 16 FET for BladeSystem c-Class 657787-B21
HP BladeSystem NOTE: For detailed interconnect options, consult the specific interconnect QuickSpecs:
c-Class SAN http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html.
Interconnects NOTE: Interconnect bays 1 and 2 support the network (i.e. Ethernet capable) interconnects. These
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 24
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
bays connect to the included network adapter ports in the server blades (either embedded ports on
G7 and earlier server blades or FlexibleLOM adapter(s) on Gen8 and later server blades) via the
NonStop passive midplane. An enclosure must be configured with at least a network interconnect
(listed above) in interconnect bay 1.
NOTE: Interconnect bays 3 through 8 support all interconnects. These bays connect to the mezzanine
slots in the server blades via the NonStop passive midplane. Interconnect bays 3 and 4 must contain
the same type of interconnect (network, SAN, SAS, etc) as they connect to the same mezzanine slot.
Likewise for interconnect bays 5, 6, 7, and 8.
NOTE: The HP BladeSystem c-Class interconnects ship as single units unless otherwise noted.
Interconnects must be ordered in quantities of two for redundancy support.
NOTE: Options to specific c-Class interconnects are not included in the list below. Consult the
individual interconnect QuickSpecs to obtain part numbers for interconnect options such as cables,
SFPs, etc.
NOTE: HP Fibre Channel interconnect switches and modules supporting up to a 4Gbps internal port
downlink speed (connection speed from the server blades to the interconnect) (SKU 403626-B21) are
supported on all c7000 enclosures.
NOTE: HP Fibre Channel interconnect switches and modules supporting up to an 8Gbps internal port
downlink speed (connection speed from the server blades to the interconnect) (SKUs 466482-B21,
572018-B21, AJ820B, AJ821B, AJ822B, AW563A, and AW564A) are supported on all c7000
enclosures.
NOTE: HP Fibre Channel interconnect switches and modules supporting up to a 16Gbps internal port
downlink speed (connection speed from the server blades to the interconnect) (SKUs C8S45A,
C8S46A, C8S47A, 751465-B21, and 778720-B21) are supported on c7000 enclosures with the
following SKUs: 5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21. A c7000 Platinum enclosure (SKUs
6XXXXX-B21 and 7XXXXX-B21) is required to permit the 16Gbps speed on the internal downlink
ports. A c7000 enclosure with SKU 5XXXXX-B21 will operate the internal ports up to 8Gbps.
HP Virtual Connect 16Gb 24-port Fibre Channel Module for c-Class BladeSystem 751465-B21
HP Virtual Connect 16Gb 24-port Fibre Channel TAA Module for c-Class BladeSystem 778720-B21
HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 466482-B21
HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem 572018-B21
HP 4GB Fibre Channel Pass-thru Module for c-Class BladeSystem 403626-B21
Brocade 8/12c SAN Switch for BladeSystem c-Class AJ820B
Brocade 8/24c SAN Switch for BladeSystem c-Class AJ821B
Brocade 8/24c Power Pack+ SAN Switch for BladeSystem c-Class AJ822B
Cisco MDS 8/12c Fabric Switch for HP BladeSystem c-Class AW563A
Cisco MDS 8/24c Fabric Switch for HP BladeSystem c-Class AW564A
Cisco MDS 9124e Switch for BladeSystem c-Class 12-port Upgrade LTU T5169A
Brocade 16Gb/28 SAN Switch for BladeSystem c-Class C8S46A
Brocade 16Gb/16 SAN Switch for BladeSystem c-Class C8S45A
Brocade 16Gb/28 SAN Switch Power Pack+ for BladeSystem c-Class C8S47A
Brocade 8/16Gb Embedded FC Switch 12-port Upgrade LTU T5517A
HP MDS 8/12c Fabric Switch 12-port Upgrade LTU TA804A
NOTE: Licensed per switch.
HP StoreFabric Data Center Network Manager BladeSystem LTU TC367A
NOTE: Installed on DCNM Server, each license can be assigned to only one switch.
HP MDS Enterprise Package for BladeSystem c-Class LTU TC317A
NOTE: Licensed per switch.
HP SAS Switch NOTE: For detailed interconnect options, consult the specific interconnect QuickSpecs:
http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html.
NOTE: Options to specific c-Class interconnects are NOT included in the list below. Consult the
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 25
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
individual interconnect QuickSpecs to obtain part numbers for interconnect options such as cables,
SFPs, etc.
NOTE: Interconnect Bay 1 must contain one of the Ethernet capable interconnect modules.
NOTE: The HP BladeSystem c-Class interconnects ship as single units unless otherwise noted.
Interconnects must be ordered in quantities of two for redundancy support.
NOTE: The HP 6Gb SAS switches are supported on c7000 enclosures with the following SKUs:
5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
HP 6Gb SAS Switch Single Pack for HP BladeSystem c-Class BK763A
HP 6Gb SAS Switch Dual Pack for HP BladeSystem c-Class BK764A
HP BladeSystem NOTE: For detailed interconnect options, consult the specific interconnect QuickSpecs:
InfiniBand http://h18004.www1.hp.com/products/blades/components/c-class-interconnects.html.
Interconnects NOTE: Options to specific c-Class interconnects are NOT included in the list below. Consult the
individual interconnect QuickSpecs to obtain part numbers for interconnect options such as cables,
SFPs, etc.
NOTE: Interconnect Bay 1 must contain one of the Ethernet capable interconnect modules.
NOTE: The HP BladeSystem c-Class interconnects ship as single units unless otherwise noted.
Interconnects must be ordered in quantities of two for redundancy support.
NOTE: The HP QDR InfiniBand Switches are supported on c7000 enclosures with the following SKUs:
5XXXXX-B21, 6XXXXX-B21, and 7XXXXX-B21.
NOTE: The HP FDR InfiniBand Switches are supported on c7000 enclosures with the following SKUs:
686610-B21, 686611-B21, and 7XXXXX-B21.
HP 4X QDR QLogic InfiniBand Switch Module for c-Class BladeSystem 505958-B21
QLogic InfiniBand 4X QDR Management Module for c-Class BladeSystem 505959-B21
HP 4X QDR InfiniBand Switch Module for c-Class BladeSystem 489184-B21
HP 4X FDR InfiniBand Managed Switch Module for c-Class BladeSystem 648311-B21
HP 4X FDR InfiniBand Switch Module for c-Class BladeSystem 648312-B21
HP Insight Software Insight Control
NOTE: Licenses ship without media. The Insight Management Media Kit can be ordered separately, or
can be downloaded at: http://www.hp.com/go/insightupdates.
NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via
fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical
Support Service.
NOTE: For additional license kits, please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12631_na/12631_na.html.
HP Insight Control Server Provisioning Media Kit BD883A
NOTE: HP Insight Control 7.2 introduced Insight Control server provisioning, a new
capability ideal for multi-server OS and firmware provisioning to ProLiant and
BladeSystem servers. Insight Control server provisioning is included and licensed as
part of HP Insight Control. A media kit, "HP Insight Control server provisioning USB
media kit" (# BD883A), including a USB, is available for customers who require a
physical copy of the media loaded with Insight Control server provisioning software.
Please note that this media kit is separate and in addition to the HP Insight
Management DVD Media Kit (C6N31A).
HP Insight Management Media Kit C6N31A
NOTE: The HP Insight Management Media Kit (C6N31A) contains DVDs without
licenses. Contains HP Systems Insight Manager, HP Insight Control, HP Matrix
Operating Environment, and Virtual Connect Enterprise Manager software. Uses an
integrated installer to perform quick and accurate software installation and updates.
HP OneView Software HP OneView incl 3yr 24x7 Supp Enclosure Bundle 16 Svr E-LTU E5Y41AAE
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 26
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
NOTE: Server provisioning capability (i.e. 'Insight Control server provisioning') is included and licensed
as part of HP OneView. This capability is ideal for multi-server OS and driver provisioning to ProLiant
and BladeSystem servers. A media kit ("HP Insight Control server provisioning USB media kit",
BD883A), which includes a USB flash drive, is available for customers who require a physical copy of
the software on media. This media kit is separate and in addition to the "HP OneView Media Kit",
E5Y37A.
NOTE: OneView licenses ship without media. The HP OneView Media Kit can be ordered separately
(E5Y37A) or can be downloaded at: http://www.hp.com/go/oneview.
HP OneView Media Kit Phys No Lic E5Y37A
HP iLO Advanced for HP iLO Advanced for BladeSystem including 1yr 24x7 Support Eight Server License 512489-B21
BladeSystem License
HP Virtual Connect HP Virtual Connect Enterprise Manager including 1yr 24x7 Support Single c7000 459864-B21
Enterprise Manager Enclosure Lic
NOTE: This license (459864-B21) allows One BL-c7000 enclosure to be managed with VCEM.
Customer will receive a printed license entitlement certificate via physical shipment. The license
entitlement certificate must be redeemed online or via fax to obtain the license activation key(s).
Includes one year of 24 x 7 HP Software Technical Support and Update Service.
NOTE: For additional license kits, please visit:
http://h18000.www1.hp.com/products/quickspecs/12860_na/12860_na.html
HP c-Class Storage HP D2200sb PCIe Storage Blade AP880A
Blades NOTE: Please see the HP D2200sb Storage Blade QuickSpecs for technical
specifications and additional information at:
http://h18000.www1.hp.com/products/quickspecs/13714_na/13714_na.html
HP D2220sb PCIe and StoreVirtual VSA Bundle QW914A
NOTE: Includes the D2220sb Storage Blade and a single HP StoreVirtual VSA license. VSA software is
installed in a virtual machine on a VMware ESX/ESXi & Microsoft Hyper-V host server adjacent to the
D2220sb.
NOTE: Includes 3yr NBD Parts-Only Warranty Service for D2220sb hardware.
NOTE: Includes 3yr 9x5 remote technical support for HP StoreVirtual VSA software and free updates.
NOTE: HP StoreVirtual VSA is supported on VMware ESX/ESXi & Microsoft Hyper-V.
HP D2220sb PCIe w/(12) 900 GB 6G SAS HDD Bundle QW915A
NOTE: Includes 3yr NBD Parts-Only Warranty Service for D2220sb hardware
HP D2220sb Build-to-order Storage Blade QW917A
NOTE: Includes 3yr NBD Parts-Only Warranty Service
HP D2220sb Configure-to-order Storage Blade QW918A
NOTE: Includes 3yr NBD Parts-Only Warranty Service
NOTE: The D2220sb requires a c7000 Enclosure configuration with 10 fans.
NOTE: Please see the HP D2220sb Storage Blade QuickSpecs for technical specifications and
additional information at:
http://h18000.www1.hp.com/products/quickspecs/14507_na/14507_na.html.
HP BL c-Class PCI Express Mezzanine Pass Thru Option Kit 431643-B21
NOTE: The HP PCI Express Mezzanine Pass-Thru Card (P/N 431643-B21) is required to
support an expansion blade with the ProLiant BL620c G7 Server Blade. Up to two
expansion blades are supported per server mix and match (Ultrium Tape,
D2220sb/D2220sb PCIe Storage, and/or PCI Expansion Blades). See the "Expansion
blade" section later in this document for more information.
HP StoreEasy 3840 Gateway Storage Blade E7X08A
HP Expansion Blades HP BLc PCI Expansion Blade 448018-B21
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 27
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
NOTE: Please see the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12753_na/12753_na.html
HP BL c-Class PCI Express Mezzanine Pass Thru Option Kit 431643-B21
NOTE: The HP PCI Express Mezzanine Pass-Thru Card (P/N 431643-B21) is required to
support an expansion blade with the ProLiant BL620c G7 Server Blade. Up to two
expansion blades are supported per server mix and match (Ultrium Tape,
D2220sb/D2220sb PCIe Storage, and/or PCI Expansion Blades). See the "Expansion
blade" section later in this document for more information.
HP Ultrium Tape Blades HP StoreEver LTO-5 Ultrium SB3000c Tape Blade BS580B
HP StoreEver LTO-4 Ultrium SB1760c Tape Blade AQ697B
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
http://h18000.www1.hp.com/products/quickspecs/12729_na/12729_na.html.
HP BL c-Class PCI Express Mezzanine Pass Thru Option Kit 431643-B21
NOTE: The HP PCI Express Mezzanine Pass-Thru Card (P/N 431643-B21) is required to
support an expansion blade with the ProLiant BL620c G7 Server Blade. Up to two
expansion blades are supported per server mix and match (Ultrium Tape,
D2220sb/D2220sb PCIe Storage, and/or PCI Expansion Blades). See the "Expansion
blade" section later in this document for more information.
HP Power Cords NOTE: For power cable information, please visit:
http://h18000.www1.hp.com/products/servers/proliantstorage/power-protection/options/power-
cable.html.
HP Intelligent Power Distribution Units Power cords
NOTE: Order with HP Single Phase FIO Intelligent Power Module for c-Class BladeSystem (677595-
B21). These power cables enable Power Discovery Services communications between the HP
BladeSystem c7000 Enclosure and HP Intelligent PDUs.
NOTE: These power cables are designated by bright blue IEC connectors.
HP 1.37m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK744A
HP 2.0m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK738A
HP 3.0m 250V 16A C19-C20 WW Single IPD Enabled Jumper Cord TK742A
HP C19 - C20 Jumper Cords
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord AF575A
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord AF574A
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord 295633-B22
HP C19 - C20 WW 250V 16Amp 4.5m Jumper Cord E7804A
HP High Line Power Cords 200 - 240V AC
HP C19 -Nema L6-30P US/CA 250V 16Amp 4.5m Power Cord E7805A
HP C19 - Nema L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord AF593A
HP 240 VAC 4.5M Unterminated End NA Power Cord E7806A
HP High Voltage Power Cords 277V AC, 380V DC
NOTE: Power cables J6W98A, J6W99A, and J6X00A are intended for 277VAC or
380VDC APP Saf-D-Grid to APP Saf-D-Grid applications.
NOTE: Power cables J6X01A, J6X02A, and J6X03A are intended for 277VAC APP Saf-
D-Grid to LS-25 applications.
HP SDGRD-SDGRD 380V 15A DC 0.76m Jpr Crd J6W98A
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 28
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
HP SDGRD-SDGRD 380V 15A DC 1.37m Jpr Crd J6W99A
HP SDGRD-SDGRD 380V 15A DC 2.0m Jpr Crd J6X00A
HP SDGRD-LS25 277V 15A AC 0.76m Jpr Crd J6X01A
HP SDGRD-LS25 277V 15A AC 1.37m Jpr Crd J6X02A
HP SDGRD-LS25 277V 15A AC 2.0m Jpr Crd J6X03A
HP Uninterruptible NOTE: Additional HP Uninterruptable Power Systems (UPSs) are available than those listed here. For a
Power Systems (UPSs) complete list of all HP UPSs and additional information, please visit
http://www.hp.com/go/rackandpower.
R5000 Uninterruptible Power System (UPS)
HP R5KVA 3U L630 High Voltage NA/JP Uninterruptible Power System AF460A
R7000 Uninterruptible Power System (UPS)
HP R7KVA 4U 50A High Voltage NA/JP Uninterruptible Power System AF462A
HP R5KVA and R7KVA 3U Extended Runtime Module AF464A
HP R8000/3 Uninterruptible Power System (UPS)
HP R8000/3 8000kVA Three Phase NA 6U Rackmount Uninterruptible Power System AF431A
HP R12000/3 Uninterruptible Power System (UPS)
HP R12000/3 12000VA Three Phase NA 6U Rackmount Uninterruptible Power System AF429A
HP Parallel 3 Phase Uninterruptible Power Systems (UPS RP36000/3)
HP RP36000/3 36000VA Three Phase NA Uninterruptible Power System AF438A
Expansion modules for RP36000/3 UPS
HP RP12000/3 12000VA Three Phase NA 6U Rackmount Uninterruptible Power AF436A
System
HP Power Distribution NOTE: A pair of PDUs must be ordered for AC feed redundancy.
Units (PDUs) NOTE: Additional HP Power Distribution Units (PDUs) are available than those listed below. For a
complete list of all HP PDUs, please visit: http://www.hp.com/go/rackandpower.
HP Basic Power Distribution Units (bPDUs)
HP 4.9kVA 208 Volt L6-30 Input (24xC13/6xC19) NA/JP Basic PDU H5M59A
HP 8.6kVA 208 Volt L15-30 3-Phase Input (24xC13/6xC19) NA/JP Basic PDU H5M62A
HP 8.6kVA 208 Volt L21-30 3-Phase Input (24xC13/3xC19/3xNEMA 5-20R) NA/JP H5M64A
Basic PDU
HP Modular Power Distribution Units (PDU Cores)
NOTE: Modular PDU Cores do not include extension bars.
HP 4.9kVA 24A High Voltage NA/JP Core Modular Power Distribution Unit 252663-D74
HP 8.3kVA 40A High Voltage NA/JP Core Modular Power Distribution Unit 252663-D75
HP 8.6kVA 24A Three Phase NA/JP Modular Power Distribution Unit AF512A
HP 14.4kVA 40A Three Phase NA/JP Modular Power Distribution Unit AF519A
HP 17.3kVA 48A Three Phase NA/JP Modular Power Distribution Unit AF511A
HP Remote Monitoring Power Distribution Units (mPDUs)
HP 4.9kVA 208 Volt L6-30 Input (20xC13/4xC19) NA/JP Monitored PDU D9N47A
HP 8.6kVA 208 Volt L15-30 3-Phase Input (18xC13/3xC19) NA/JP Monitored PDU D9N51A
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 29
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
HP 8.6kVA 208 Volt L21-30 3-Phase Input (20xC13/3xC19/3xNEMA 5-20R) NA/JP D9N53A
Monitored PDU
HP 17.3kVA 208 Volt IEC309 60A 3-Phase Input (24xC13/3xC19) NA/JP Monitored D9N54A
PDU
HP Environmental Sensor for Remote Monitored PDUs E2D53A
NOTE: The HP Environmental Sensor collects temperature and humidity information
in the rack and can be monitored via the local LCD display or remotely using Telnet or
a standard web interface. The sensor can also monitor the status of two user
supplied contact devices.
HP Intelligent Power Distribution Units (iPDUs)
HP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit AF520A
HP 8.6kVA 24A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit AF522A
HP 17.3kVA 48A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit AF523A
HP Data Center Racks NOTE: Additional HP Data Center racks are available than those listed below. For information on the
full line of HP Data Center Racks and rack accessories, please see
http://www.hp.com/go/rackandpower.
HP 11000 G2 Series Racks
HP 11642 1075mm Pallet Rack H6J65A
HP 11642 1200mm Pallet Universal Rack H6J67A
HP 11842 1200mm Pallet Rack H6J69A
HP 11648 1075mm Pallet Rack H6J87A
HP 11636 1075mm Pallet Universal Rack H6J77A
HP 11622 1075mm Pallet Rack H6J83A
HP Intelligent Series Rack
HP 636 1075mm Pallet Intelligent Rack BW895A
HP 642 1075mm Pallet Intelligent Rack BW903A
HP 647 1075mm Pallet Intelligent Rack BW911A
HP Location Discovery Services
NOTE: For information on HP Location Discovery Services, please see:
http://www.hp.com/go/rackandpower.
HP 47U Location Discovery Kit BW947A
HP 42U Location Discovery Kit BW946A
HP 36U Location Discovery Kit BW945A
HP Tape Backup NOTE: For the complete range of tape drives, autoloaders, libraries and media see:
http://www.hp.com/go/tape. For hardware and software compatibility of HP tape backup products
see: http://www.hp.com/storage/SPOCK.
HP StoreEver LTO-6 Ultrium 6250 Tape Drive in 1U Rack-mount Kit C0L99A
HP StoreEver LTO-6 Ultrium 6650 SAS Internal Tape Drive EH963A
HP StoreEver LTO-6 Ultrium 6650 SAS External Tape Drive EH964A
HP StoreEver LTO-6 Ultrium 6250 Internal Tape Drive EH969A
HP StoreEver LTO-6 Ultrium 6250 External Tape Drive EH970A
HP Rack Options NOTE: For additional information regarding Rack Options, please see the following URL:
http://www.hp.com/go/rackandpower.
HP TFT7600 G2 KVM Console and Monitor
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 30
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount
monitors, keyboards and all related options please see the following URL:
http://www.hp.com/go/kvm.
HP TFT7600 G2 KVM Console Rackmount Keyboard US Monitor AZ870A
HP TFT7600 G2 KVM Console Rackmount Keyboard US TAA Monitor AZ885A
HP KVM Server Console Switches
HP Server Console 0x2x8 Port Analog Switch AF616A
HP Server Console 0x2x16 Port Analog Switch AF617A
HP Server Console Switch G2 with Virtual Media & CAC
HP 0x2x16 KVM Server Console Switch G2 with Virtual Media CAC Software AF618A
HP 0x2x32 KVM Server Console Switch G2 with Virtual Media CAC Software AF619A
HP IP Console Switch G2 with Virtual Media & CAC
HP 1x1Ex8 KVM IP Console Switch G2 with Virtual Media CAC Software AF620A
HP 2x1Ex16 KVM IP Console Switch G2 with Virtual Media CAC Software AF621A
HP 4x1Ex32 KVM IP Console Switch G2 with Virtual Media CAC Software AF622A
HP KVM Interface Adapters
HP KVM Console USB Interface Adapter AF628A
HP KVM Console USB 2.0 Virtual Media CAC Interface Adapter AF629A
HP KVM Console Serial/Power G2 Interface Adapter AF625A
HP Care Pack Services NOTE: Some options, including Fibre Channel and InfiniBand switches for the HP c-Class BladeSystem,
are not covered under the c7000 enclosure Care Packs and carry separate Care Packs. Care Pack
service level support for these options should always be uplifted to match existing storage or server
service level. Please view the option QuickSpecs or contact your HP sales representative or HP
authorized ServiceOne partner for Care Pack information.
NOTE: Additional HP Care Pack services can be found at: http://www.hp.com/go/cpc.
Proactive Care Services
HP 3 year 4 hour 24x7 c7000 Enclosure Proactive Care Service U3C33E
HP 3 year 6 hour Call To Repair 24x7 c7000 Enclosure Proactive Care Service U3C36E
HP 3 year 4 hour 24x7 c7000 Enclosure with Insight Control Proactive Care Service U3P10E
HP 3 year 6 hour Call To Repair 24x7 c7000 Enclosure with Insight Control Proactive U3P13E
Care Service
HP Proactive Care Personalized Support - Environmental Option
HP 3 year ISS Proactive Care Personalized Support U6W98E
Installation & Start-up Services
HP Startup BladeSystem c7000 Infrastructure Service UE602E
HP Enhanced Network Installation and Startup Service for HP BladeSystem UE603E
HP Hardware Install c-Class Enclosure and Server Blade Service UE494E
HP Installation during Non Standard Hours c7000 Enclosure & Blade Service UG870E
HP Flexible Care Pack Services for your Integrity BladeSystem Enclosure
NOTE: Please contact your HP sales representative or HP authorized ServiceONE partner for
additional Flexible Care Pack information.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 31
QuickSpecs HP BladeSystem c7000 Enclosure
Related Options
Mission Critical Services
Proactive 24 Service - Mission Critical proactive environment 24x7 4hr onsite HW HA111A3#6Q6
support
Critical Service - Mission Critical proactive environment 6-Hour Call-to-Repair onsite HA112A3#6Q6
HW support
Installation & Start-up Services
HP BladeSystem c7000 Infrastructure Installation and Startup Service for Blade HA114A1#57A
Hardware and Insight Control Software
HP Enhanced Network Installation and Startup Service for HP BladeSystem HA124A1#56H
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 32
QuickSpecs HP BladeSystem c7000 Enclosure
Power Input Module and Power Supply Specifications
NOTE: HP highly recommends using the HP Power Advisor tool to ensure the number of power supply options you have selected
can fully support your BladeSystem configuration and to review maximum system power ratings for facilities planning purposes.
HP Power Advisor is available at: http://www.hp.com/go/hppoweradvisor.
Power Input Module Specifications
1
Power Input Module Power HP Power Rated Input Input Supported Power Supported
Supply Kits7
Connection Discovery Voltage Frequency c7000
Enclosures11
Services
Single Phase AC 6x IEC-320 C20 Supported3 200-240 VAC 50-60 Hz 2650W Platinum9,10a 4XXXXX-B21
Intelligent blue power 2400W Platinum8,9,10b 4XXXXX-B22
(677595-B21) connectors2,3,4 2400W Gold8,9,10c 4XXXXX-B23
2250W9,10d 5XXXXX-B21
Single Phase AC 6x IEC-320 C20 Not
6XXXXX-B21
(413379-B21) power supported
7XXXXX-B21
connectors 5
Three Phase AC Two 3.05m (10 ft) 200-208 VAC
NA/JPN power cables with line to line,
(413380-B21)9 NEMA L15-30p 3-phase delta
connectors
-48V DC 45DG 4AWG 1/4 2H 40-60 VDC N/A 2250W -48VDC
(AH331A) terminal lugs (AH332A)
High Voltage 6x APP Saf-D-Grid 277 VAC, 50-60 Hz (AC), 2650W Universal
(753623-B21) receptacle 380 VDC N/A (DC) (753618-B21 and
connectors12 753619-B21)
1. See the “Technical Specifications” section for additional power specifications.The blue power connectors indicate HP Power
Discovery Services capability.HP Power Discovery Services are enabled when used with an Intelligent Power Distribution Unit
(iPDU), iPDU cables, and the Platinum power supply kits 733460-B21, 733459-B21, 517521-B21, or 588603-B21. See the
iPDU, iPDU cable, and c-Class Power Supply sections for these options.Accept IEC C19-C20 and C19-C20 Intelligent Power
Distribution Unit (iPDU) power cables. One WW 250W C19-C20 2.0m (non-iPDU) power cable is included per supported power
supply. iPDU power cables are ordered separately.Accept IEC C19-C20 power cables. One WW 250W C19-C20 2.0m power
cable is included per supported power supply. Rated 220 to 240 VAC line-to-neutral. The enclosure will not operate from
higher line-to-line voltage with the WYE wall plug configuration. This power input module is configured to provide 220 to
240 VAC to the power supplies.Each enclosure must include only one type of power supply. Mixing of power supplies is not
supported, except during hot swaps to different level or higher efficient power supplies. The Onboard Administrator will
exhibit a mismatch error due to mixed power supplies until all power supplies are matched.The three-phase power input
modules (413380-B21 and 413381-B21) require a minimum of 6 fans and 3 power supplies. For full redundancy, 6 power
supplies are required.Supported HP power supply kits include:2650W Platinum: 733460-B21 (6-pack) and 733459-B21
(single). 2400W Platinum: 517521-B22 (6-pack) and 588603-B21 (single). 2400W Gold: 517521-B21 (6-pack) and
499243-B21 (single). 2250W: 412138-B21 (single).The Onboard Administrator firmware must be at least the minimum
version that supports all components installed within the enclosure. Power cables with APP Saf-D-Grid connectors are
ordered separately.
Power Supply Specifications
HP 2650 Watt Platinum Hot Plug Power Supply
Part Number 733459-B21 (single), 733460-B21 (6-pack)
Input Voltage Range (Vrms) 200-240
Frequency Range (Nominal) (Hz) 50 / 60
Nominal Input Voltage (Vrms) 200 208 220 230 240
Maximum Rated Output Wattage (Watts) 2650
Nominal Input Current (Arms) 14.5 13.9 13.1 12.5 12.0
Maximum Rated Input Wattage (Watts) 2898 2901 2904 2887 2884
Maximum Rated VA (Volt-Amp) 2896 2888 2887 2882 2878
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 33
QuickSpecs HP BladeSystem c7000 Enclosure
Power Input Module and Power Supply Specifications
Efficiency (%) at Maximum Rated Output Wattage 91.2 91.3 91.4 91.8 91.9
Power Factor (Minimum) 0.98
Leakage Current (mA) 0.97 1.01 1.06 1.11 1.16
Maximum Inrush Current (A peak) 100
Maximum Inrush Current duration (mS) 10
Maximum British Thermal Unit Rating (BTU/Hr) 9888 9899 9910 9850 9840
HP 2400 Watt Platinum Hot Plug Power Supply
Part Number 588603-B21 (single), 517521-B22 (6-pack)
Input Voltage Range (Vrms) 200-240
Frequency Range (Nominal) (Hz) 50 / 60
Nominal Input Voltage (Vrms) 200 208 220 230 240
Maximum Rated Output Wattage (Watts) 2450
Nominal Input Current (Arms) 13.9 13.4 12.6 12.0 11.4
Maximum Rated Input Wattage (Watts) 2692 2692 2678 2678 2663
Maximum Rated VA (Volt-Amp) 2778 2778 2762 2762 2747
Efficiency (%) at Maximum Rated Output Wattage 91 91 91.5 91.5 92
Power Factor (Minimum) 0.98
Leakage Current (mA) 0.97 1.01 1.06 1.11 1.16
Maximum Inrush Current (A peak) 100
Maximum Inrush Current duration (mS) 10
Maximum British Thermal Unit Rating (BTU/Hr) 9186 9186 9136 9136 9086
HP 2400 Watt Gold Hot Plug Power Supply
Part Number 499243-B21 (single), 517521-B21 (6-pack)
Input Voltage Range (Vrms) 200-240
Frequency Range (Nominal) (Hz) 50 / 60
Nominal Input Voltage (Vrms) 200 208 220 230 240
Maximum Rated Output Wattage (Watts) 2450
Nominal Input Current (Arms) 14.15 13.58 12.81 12.23 11.70
Maximum Rated Input Wattage (Watts) 2742 2737 2730 2724 2720
Maximum Rated VA (Volt-Amp) 2830 2825 2817 2812 2807
Efficiency (%) at Maximum Rated Output Wattage 87.5 87.7 87.9 88.1 88.2
Power Factor (Minimum) 0.98
Leakage Current (mA) 0.97 1.01 1.06 1.11 1.16
Maximum Inrush Current (A peak) 100
Maximum Inrush Current duration (mS) 5
Maximum British Thermal Unit Rating (BTU/Hr) 9356 9338 9313 9295 9280
HP 2250 Watt -48VDC Hot Plug Power Supply
Part Number AH332A (single)
Input Voltage Range (V DC) 40-60
Frequency Range (Nominal) (Hz) N/A
Nominal Input Voltage (Vrms) 48
Maximum Rated Output Wattage (Watts) 2250
Nominal Input Current (Arms) 53.15
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 34
QuickSpecs HP BladeSystem c7000 Enclosure
Power Input Module and Power Supply Specifications
Maximum Rated Input Wattage (Watts) 2523
Maximum Rated VA (Volt-Amp) 2523
Efficiency (%) at Maximum Rated Output Wattage 89.2
Power Factor (Minimum) 1.00
Leakage Current (mA) N/A
Maximum Inrush Current (A peak) 200
Maximum Inrush Current duration (mS) 5
Maximum British Thermal Unit Rating (BTU/Hr) 8607
HP 2650 Watt Universal Hot Plug Power Supply
Part Number 753618-B21 (single), 753619-B21 (6-pack)
Input Voltage Range (Vrms) 277 VAC, 380 VDC
Frequency Range (Nominal) (Hz) 50 / 60 (AC), N/A (DC)
Nominal Input Voltage (Vrms) 277 VAC 380 VDC
Maximum Rated Output Wattage (Watts) 2650
Nominal Input Current (A rms) 10.40 7.51
Maximum Rated Input Wattage (Watts) 2868 2853
Maximum Rated VA (Volt-Amp) 2881 2853
Efficiency (%) at Maximum Rated Output Wattage 92.4 92.9
Power Factor (Minimum) 0.996 (AC), 1.000 (DC)
Leakage Current (mA) 1.16 N/A
Maximum Inrush Current (A peak) 100
Maximum Inrush Current duration (mS) 10
Maximum British Thermal Unit Rating (BTU/Hr) 9785 9735
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 35
QuickSpecs HP BladeSystem c7000 Enclosure
Fan Bay and Device Bay Numbering and Population Guidelines
Fan bay numbering
Fans must be placed in the following bays
Number of Fans Fan Bays Used
4 4, 5, 9, 10
6 3, 4, 5, 8, 9, 10
8 1, 2, 4, 5, 6, 7, 9, 10
10 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
Half-height device bay numbering
1. Device Bay 1 9. Device Bay 9
2. Device Bay 2 10. Device Bay 10
3. Device Bay 3 11. Device Bay 11
4. Device Bay 4 12. Device Bay 12
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 36
QuickSpecs HP BladeSystem c7000 Enclosure
Fan Bay and Device Bay Numbering and Population Guidelines
5. Device Bay 5 13. Device Bay 13
6. Device Bay 6 14. Device Bay 14
7. Device Bay 7 15. Device Bay 15
8. Device Bay 8 16. Device Bay 16
Full-height device bay numbering
1. Device Bay 1 5. Device Bay 5
2. Device Bay 2 6. Device Bay 6
3. Device Bay 3 7. Device Bay 7
4. Device Bay 4 8. Device Bay 8
Full-height and half-height blade mixed configurations
The c7000 enclosure is divided into 4 zones by the vertical support metalwork. Within each zone a removable divider is used to
support half height devices. To install a full-height blade in any zone this divider must be removed. As a consequence a zone can
only contain either full-height server blades or half-height server blades.
NOTE: Expansion blades can be installed in the same zone as both full-height, single-wide and half-height blades. For more
information, please see the "Expansion blades" later in this document.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 37
QuickSpecs HP BladeSystem c7000 Enclosure
Fan Bay and Device Bay Numbering and Population Guidelines
The following device bays are located in each zone:
Zone Half-Height Device Bays Full-Height Device Bays
1 1, 9, 2, 10 1, 2
2 3, 11, 4, 12 3, 4
3 5, 13, 6, 14 5, 6
4 7, 15, 8, 16 7, 8
Expansion blades
Expansion blades consist of storage blades, tape blades, and the PCI Expansion Blade. Up to 8 expansion blades are supported
per HP BladeSystem c-Class c7000 Enclosure. Expansion blades may be installed in the same zone as half-height and full-height,
single-wide server blades. Expansion blades are not supported with full-height, double-wide server blades. An expansion blade
is installed directly adjacent to a server blade, also known as a partner server blade. Expansion blade population rule best
practices are detailed below. For additional expansion blade rules and guidelines, please see the documentation that ships with
the enclosure and expansion blade. HP recommends consulting your HP sales representative to confirm the validity of any
configuration.
Figure 1 Installing an expansion blade adjacent to a half- Figure 2 Installing a single expansion blade adjacent to a
height server blade. full-height, single-wide server blade.
Expansion blade population best practices for half-height server blades
1. One half-height partner server blade supports one expansion blade (Figure 1).
2. Identify the partner server blade to be installed with the expansion blade. The two blades always occupy a pair of slots
as follows: 1 & 2, 3 & 4, 5 & 6, 7 & 8, 9 & 10, 11 & 12, 13 & 14, 15 & 16.
3. If the partner server blade is installed in an odd-numbered bay, the expansion blade is installed in the adjacent even-
numbered bay to the right.
4. If the partner server blade is installed in an even-numbered bay, the expansion blade is installed in the adjacent odd-
numbered bay to the left.
5. Each c7000 zone contains a removable divider that is used to support half-height devices. This divider is remains
installed whether the half-height devices are server or expansion blades.
Expansion blade population best practices for full-height, single-wide server blades:
1. One full-height, single-wide partner server blade supports one or two expansion blades. Figure 2 shows installation of
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 38
QuickSpecs HP BladeSystem c7000 Enclosure
Fan Bay and Device Bay Numbering and Population Guidelines
one expansion blade.
2. Identify the partner server blade to be installed with the first expansion blade. The two blades always occupy a pair of
slots, as follows: 9 & 10, 11 & 12, 13 & 14, 15 & 16.
3. The partner server blade is installed in an odd-numbered bay. The first expansion blade is installed on the lower row of
the enclosure in an even-numbered bay (slots 10, 12, 14 or 16) adjacent to the partner server blade.
4. If only a single expansion blade is installed:
a. A half-height server blade may be installed in the empty bay directly above the expansion blade; this server
blade cannot be partnered with the expansion blade. A coupler bracket is installed on the expansion blade. A
coupler bracket is not installed on the server blade. A coupler bracket is included with each expansion blade.
b. If no device is desired in the empty bay above the expansion blade, a device bay blank is installed.
c. The upper half-height server blade or device bay blank must be removed before removing the lower expansion
blade.
5. If a second expansion blade is installed:
a. It is always located directly above the first installed expansion blade. A coupler bracket is installed on the lower
expansion blade. A coupler bracket is not installed on the upper expansion blade. A coupler bracket is included
with each expansion blade.
b. Two storage blades, two tape blades, two PCI Expansion Blades, or a mixture of any two. For a mixed
configuration that contains a storage blade, the storage blade is installed on the bottom bay and the tape blade
or PCI Expansion Blade is installed on the top bay.
c. The upper expansion blade must be removed before removing the lower expansion blade.
6. When partnering an expansion blade with a ProLiant BL620c G7 Server Blade, an HP PCI Express Mezzanine Pass-Thru
Card for BladeSystem c-Class (431643-B21) is required. This card is installed in the mezzanine 3 connector in the server
blade for a lower bay expansion blade installation and a second card in installed in mezzanine 2 connector if a second
expansion blade is required.
7. The HP ProLiant BL680c G7 Server Blade is a full-height, double-wide device. It does not support expansion blades.
Device bay and fan population guidelines
The device bay and fan bay population rule best practices are provided below. HP recommends consulting your HP sales
representative to confirm the validity of any configuration.
Summary:
Supported Device Bays Minimum Number Supported
Configuration Half-Height Bays Full-Height Bays of Fans Fan Bays
No more than 1 full-height or 2
1, 9, 2, 10 1, 2 4 4, 5, 9, 10
half-height device bays occupied
No more than 4 full-height or 8
1, 9, 2, 10, 3, 11, 4, 12 1, 2, 3, 4 6 3, 4, 5, 8, 9, 10
half-height device bays occupied
At least 5 full-height or 9 half-
All All 8 1, 2, 4, 5, 6, 7, 9, 10
height device bays occupied
NOTE: Ten fans are strongly recommended in all configurations for maximum cooling efficiency and redundancy, reduced power
consumption, and reduced noise.
NOTE: Please see the complete detailed list below of device bay and fan bay population rule best practices.
Details:
1. Half-height devices are populated from top and bottom from left to right from the front of the enclosure. So the first
two half-height devices would be placed in bays 1 & 9, the second two half-height devices would be placed in bays 2 &
10, and so on until the enclosure is full. Please refer to the above section “half-height device bay numbering” for
additional information.
2. Full-height servers are populated from left to right. Please see the above section “full-height device bay numbering” for
additional information.
3. An enclosure zone can only contain either full-height server blades or half-height server blades; mixing of the two form
factors is not allowed except when connecting an expansion blade to a server partner blade. Please refer to the above
sections “Full-height and half-height blade mixed configurations” and “Expansion blades” for more information.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 39
QuickSpecs HP BladeSystem c7000 Enclosure
Fan Bay and Device Bay Numbering and Population Guidelines
4. The type and number of installed blade devices and interconnect modules determine the number of required fans.
5. The enclosure supports a minimum of 4 Active Cool 200 Fans to a maximum of 10 Active Cool 200 Fans. Ten fans are
strongly recommended for maximum cooling efficiency and redundancy, reduced power consumption, and reduced
noise.
6. For proper operation, fans and blades must be installed in the correct bays. The Onboard Administrator will ensure that
fans and blades are correctly placed before allowing systems to power on.
7. A minimum of 4 fans are required for a configuration that occupies 2 half-height device bays. Examples include up to 2
half-height, single-wide server blades, 1 half-height, double-wide server blade, 1 full-height, single-wide server blade,
or 1 half-height, single-wide server blade and 1 expansion blade. The blades are installed in zone 1 (device bays 1, 9, 2,
and/or 10). The fans are installed in fan bays 4, 5, 9, and 10.
8. A minimum of 6 fans are required for a configuration that occupies up to 8 half-height device bays. Examples include up
to 8 half-height, single-wide server blades, 4 half-height, double-wide server blades, or 2 full-height, double-wide
server blades. The blades are installed in zones 1 and 2 (device bays 1, 9, 2, 10, 3, 11, 4, and/or 12). The fans are
installed in fan bays 3, 4, 5, 8, 9, and 10.
9. A minimum of 8 fans are required for a configuration that occupies at least 9 half-height device bays. The blades can be
installed in any device bays. The fans are installed in fan bays 1, 2, 4, 5, 6, 7, 9, and 10.
10. Ten fans support all device bays. The blades can be installed in any device bays. The fans are installed in all fan bays.
11. Device bay blanks and fan bay blanks are installed in all unoccupied bays.
12. In addition to the above, please observe the following:
a. A minimum of 6 fans are required for any enclosure configured with a three-phase power input module. The fans
are installed in fan bays 3, 4, 5, 8, 9, and 10.
b. A minimum of 8 fans are required if at least one switch module is installed in interconnect bay 1, 3, 5, or 7 and at
least one switch module is installed in interconnect bay 2, 4, 6, or 8. This does not apply to pass-thru modules. The
fans are installed in fan bays 1, 2, 4, 5, 6, 7, 9, and 10.
c. Ten fans are required for a configuration with:
i. One or more HP Virtual Connect FlexFabric-20/40 F8 Modules.
ii. One or more D2220sb Storage Blades.
iii. More than half of the enclosure device bays are occupied and any quantity of D2200sb Storage Blades are
present.
iv. Nine or more BL460c G1 and/or BL460c G5 Server Blades.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 40
QuickSpecs HP BladeSystem c7000 Enclosure
Technical Specifications
HP BladeSystem Dimensions Height 17.4 in (442 mm)
c7000 Server Blade Width 17.6 in (447.04 mm)
Enclosure
Depth 32 in (813 mm)
Shipping Dimensions Height 29.88 in (759 mm)
Width 23.88 in (607 mm)
Depth 39.88 in (1013 mm)
Enclosure Weight Unboxed 148 lb (67 kg)
Shipping 191 lb (87 kg)
NOTE: The enclosure weight above includes only an empty enclosure- servers, the power input
module, power supplies, fans, interconnect modules, and Onboard Administrator(s) are not included.
The weight for the power input module, power supplies, fans, and Onboard Administrator(s) is listed
below. Please see the specific server blade and interconnect module QuickSpecs for their respective
weight.
Power Input Module 3 lbs (1.4 kg)
Weight
(minimum 1, maximum 1)
Power Supply Weight 6 lbs (2.7 kg)
(minimum 1, maximum 6)
HP Active Cool 200 Fan 4 lbs (1.8 kg)
Weight
(minimum 4, maximum
10)
Onboard Administrator 3 lbs (1.4 kg)
Weight
(minimum 1, maximum 2)
Maximum Enclosure Unboxed 482 lb (219 kg)
Weight (approximate) Shipping 525 lb (238 kg)
NOTE: The approximate maximum enclosure weight above includes 16 server blades fully configured,
the power input module, six power supplies, ten fans, eight interconnect modules, and two Onboard
Administrators.
Temperature Range Operating 50° to 95° F (10° to 35° C)
Non-Operating -22° to 140° F (-30° to 60° C)
Relative Humidity Operating 10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.
Non-Operating 5 to 95% relative humidity (Rh), 38.7°C
(101.7°F)maximum wet bulb temperature,
non-condensing.
NOTE: Operating temperature has an altitude derating of 1.8° F (1° C) per 1,000 ft (304.8 m). No direct
sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
NOTE: For detailed environmental and other installation requirements, please see the “HP
BladeSystem c-Class Site Planning Guide” at http://www.hp.com/support.
Power NOTE: HP highly recommends using the HP Power Advisor tool to ensure the number of power supply
options you have selected can fully support your BladeSystem configuration and to review maximum
system power ratings for facilities planning purposes. HP Power Advisor is available at:
http://www.hp.com/go/hppoweradvisor.
Single Phase AC Power Power connection 677595-B21: 6x IEC-320 C20 blue power
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 41
QuickSpecs HP BladeSystem c7000 Enclosure
Technical Specifications
Input Module connectors
(413379-B21) 413379-B21: 6x IEC-320 C20 power
Single Phase AC connectors
Intelligent Power NOTE: The blue power connectors indicate HP
Input Module Power Discovery Services capability. HP
(677595-B21) Power Discovery Services are enabled when
used with an Intelligent Power Distribution
Unit (iPDU), iPDU cables, and a Platinum
power supply kit.
NOTE: One WW 250W C19-C20 2.0m power
cable is included per power supply. iPDU
power cables are ordered separately.
Rated input voltage 200 to 220 VAC
Rated input frequency 50 to 60 Hz
Number of power Minimum: One (1)
supplies supported Maximum: Six (6)
2250W Power Supply Maximum output (per 2250W
(412138-B21) power supply)
Maximum output (total 13,050W
for six power supplies)
Maximum input current 13.1 A at 200 VAC
(per power supply) 12.6 A at 208 VAC
11.9 A at 220 VAC
Maximum input power 2621 VA
(per power supply)
2400W Gold Power Maximum output (per 2450W
Supply power supply)
(517521-B21, 6-pack) Maximum output (total 14,210W
(499243-B21, single) for six power supplies)
Maximum input current 13.9 A at 200 VAC
(per power supply) 13.3 A at 208 VAC
12.6 A at 220 VAC
Maximum input power 2780 VA
(per power supply)
2400W Platinum Power Maximum output (per 2450W
Supply power supply)
(517521-B22, 6-pack) Maximum output (total 14,210W
(588603-B21, single) for six power supplies)
Maximum input current 13.2 A at 200 VAC
(per power supply) 12.7 A at 208 VAC
12.2 A at 220 VAC
Maximum input power 2640 VA
(per power supply)
2650W Platinum Power Maximum output (per 2650W
Supply power supply)
(733460-B21, 6-pack) Maximum output (total 15,370W
(733459-B21, single) for six power supplies)
Maximum input current 14.4 A at 200 VAC
(per power supply) 13.8 A at 208 VAC
13.1 A at 220 VAC
Maximum input power 2880 VA
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 42
QuickSpecs HP BladeSystem c7000 Enclosure
Technical Specifications
(per power supply)
Three Phase AC NA/JPN Power connection Two 3.05m (10 ft) power cables with NEMA
Power Input Module L15-30p connectors
(413380-B21) Rated input voltage 200 to 208 VAC line to line
3-phase delta
Rated input frequency 50 to 60 Hz
Number of power Minimum: Three (3)
supplies supported Maximum: Six (6)
2250W Power Supply Maximum output (per 2250W
(412138-B21) power supply)
Maximum output (total 13,050W
for six power supplies)
Maximum input current 22.8 A at 200 VAC
per line cord 21.8 A at 208 VAC
Maximum input power 7863 VA
per line cord
2400W Gold Power Maximum output (per 2450W
Supply power supply)
(517521-B21, 6-pack) Maximum output (total 14,210W
(499243-B21, single) for six power supplies)
Maximum input current 24.2 A at 200 VAC
per line cord 23. 2 A at 208 VAC
Maximum input power 8352 VA
per line cord
2400W Platinum Power Maximum output (per 2450W
Supply power supply)
(517521-B22, 6-pack) Maximum output (total 14,210W
(588603-B21, single) for six power supplies)
Maximum input current 22.9 A at 200 VAC
per line cord 22 A at 208 VAC
Maximum input power 7920 VA
per line cord
2650W Platinum Power Maximum output (per 2650W
Supply power supply)
(733460-B21, 6-pack) Maximum output (total 15,370W
(733459-B21, single) for six power supplies)
Maximum input current 25 A at 200 VAC
per line cord 24 A at 208 VAC
Maximum input power 8640 VA
per line cord
48VDC Power Input Power connection Terminal lug: 45DG 4AWG 1/4 2H
Module Two-hole lug
(AH331A) 45 degree bend
0.25in. (6.4mm) stud hole size
0.63in. (16mm) hole spacing
Rated input voltage 40 to 60 VDC
Number of power Minimum: One (1)
supplies supported Maximum: Six (6)
2250W -48VDC Power Maximum output (per 2250W
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 43
QuickSpecs HP BladeSystem c7000 Enclosure
Technical Specifications
Supply power supply)
(AH332A) Maximum output (total 13,050W
for six power supplies)
Maximum input current 75A
(per power supply)
Maximum input power 2700W
per supply
High Voltage Power Power connection 6x APP Saf-D-Grid receptacle connectors
Input Module NOTE: Power cables with APP Saf-D-Grid
(753623-B21) connectors are ordered separately.
Rated input voltage 277 VAC, 380 VDC
Rated input frequency 50 to 60 Hz (AC), N/A (DC)
Number of power supplies Minimum: One (1)
supported Maximum: Six (6)
2650W Universal Power Maximum output (per 2650W
Supply power supply)
(753619-B21, 6-pack) Maximum output (total 15,370W
(753618-B21, single) for six power supplies)
Maximum input current 10.5 A at 277 VAC
(per power supply) 7.6 A at 380 VDC
Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd 7.1 Bels
LpAm 54 dBA
Operating
LWAd 7.2 Bels
LpAm 54 dBA
Option Kits Power Supply Option Height 8.75 in (223 mm)
Shipping Dimensions Width 8.63 in (219 mm)
Depth 35.13 in (892 mm)
Weight 8.5 lbs (3.85 kg)
Fan Option Shipping Height 8.75 in (223 mm)
Dimensions Width 9.75 in (248 mm)
Depth 15.88 in (403 mm)
Weight 4.0 lbs (1.8 kg)
BladeSystem Onboard Height 2.50 in (63.5 mm)
Administrator Option Width 9.88 in (251 mm)
Shipping Dimensions
Depth 13.50 in (343 mm)
Weight 4.0 lbs (1.8 kg)
Environmental-friendly End-of-life Management Hewlett-Packard offers end-of-life HP product return, trade-in, and
Products and Approach and Recycling recycling programs in many geographic areas. For trade-in information,
please go to http://www.hp.com/go/green. To recycle your product,
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 44
QuickSpecs HP BladeSystem c7000 Enclosure
Technical Specifications
please go to: http://www.hp.com/go/green or contact your nearest HP
sales office. Products returned to HP will be recycled, recovered or
disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment
facilities. This information (product disassembly instructions) is posted
on the Hewlett Packard web site at: http://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment
facilities as well as HP OEM customers who integrate and re-sell HP
equipment.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 45
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
Date Version History Action Description of Change:
09-Feb-2015 From Version 61 to 62 Changed Overview, Service and Support, Configuration Information
Factory Integrated Models and Related Options sections
were updated
Added Skus Added on HP BladeSystem c-Class Network
Interconnects:
751465-B21
778720-B21
466482-B21
Removed Obsolete sku removed:
AF536A
19-Dec-2014 From Version 60 to 61 Changed Notes were updated throughout the QuickSpecs
21-Nov-2014 From Version 59 to 60 Changed Subheader was added: Fan Bay and Device Bay Numbering
Populating Guidelines.
Device bay and fan population guidelines were updated
07-Nov-2014 From Version 58 to 59 Changed Overview, Pre-configured Models and Configuration
Information Factory Integrated Models sections were
updated
25-Sep-2014 From Version 57 to 58 Changed Changes were made throughout the QuickSpecs.
9-Sep-2014 From Version 56 to 57 Changed Changes were made throughout the QuickSpecs.
18-Aug-2014 From Version 55 to 56 Changed Overview, Related Options and Technical Specifications
sections were updated
Added SKUs added on configuration Information Factory Integrated
Models section:
753623-B21
753618-B21
753619-B21
C6N33ABE
Skus added on related options section:
J6W98A
J6W99A
J6X00A
J6X01A
J6X02A
J6X03A
Power Input Module and Power Supply Specifications section
added
24-Jun-2014 From Version 54 to 55 Changed Overview, Configuration Information Factory Integrated
Models, Related Option, Device Bay and Fan Bay Numbering
and Population Guidelines, Technical Specifications sections
were updated
Removed SKU 691380-B21 was deleted, HP Power Distribution Units
SKUs were deleted
Added HP Data Center Racks skus on Configuration Information
Factory Integrated Models section, HP Power Distribution
Units skus were added
10-Jun-2014 From Version 53 to 54 Changed Changes were made throughout the QuickSpec.
31-Mar-2014 From Version 52 to 53 Added HP OneView Software was added.
10-Dec-2013 From Version 51 to 52 Changed Changes were made throughout the QuickSpec.
11-Oct-2013 From Version 50 to 51 Changed Changes made to Step 5 & 6 of Configuration Information
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 46
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
and to the Related Options section.
13-Sep-2013 From Version 49 to 50 Changed Models, throughout Configuration Information - Factory
Integrated Models, and Related Options were revised.
30-Aug-2013 From Version 48 to 49 Changed Changes made in the Configuration Information, Related
Options and Technical Specifications sections.
14-Jun-2013 From Version 47 to 48 Changed 2650 Watts Platinum Hot Plug Power Supply was added
HP BladeSystem Power Sizer was removed
10-Jun-2013 From Version 46 to 47 Changed Changes made in the following sections:
Service and Support
Configuration Information - Steps 2 & 5
Related Options
28-Mar-2013 From Version 45 to 46 Changed Changes made in the North America and Canada versions
only.
15-Mar-2013 From Version 44 to 45 Changed Changed name of product throughout document.
Changes made in the HP Insight Management software,
Configuration Information: Steps 2 - 7 and Related Options
sections
01-Mar-2013 From Version 42 to 44 Removed Related Options: Removed TC276AAE, 436222-B21 and
TC277AAE from the HP Insight Software section.
19-Feb-2013 From Version 41 to 42 Added Added the What's New section
Increased mid-plane bandwidth
Intelligent Infrastructure
2400W Platinum Hot Plug Power Supply (80 Plus certified)
Single Phase Intelligent Power Module
Location Discovery Services
Support for HP Insight Control 7.2 and higher releases
Changed Changed name of product throughout document.
Changed name of HP DSB400c Storage Blade to HP D2200sb
Storage Blade throughout document.
Completely revised the Service and Support sections.
Changes made in the HP Insight Management software,
Configuration Information: Steps 2 - 7 and Related Options
sections
14-Dec-2012 From Version 40 to 41 Changed Changed SB40c to D2200sb throughout the QuickSpec.
Changes made to Insight Management section.
Completely revised the Service and Support sections.
Changes made throughout the Configuration Information
and Related Options sections
24-Sep-2012 From Version 39 to 40 Changed Changes were made in HP BladeSystem c-Class Overview,
Configuration Information Factory Integrated Models and
Related Options sections.
31-Aug-2012 From Version 38 to 39 Changed Changes made throughout the QuickSpec.
14-May-2012 From Version 37 to 38 Changed Changes made in the Related Options section.
26-Mar-2012 From Version 36 to 37 Changed Changes made to the HP Optical Drives.
06-Mar-2012 From Version 35 to 36 Added Added in the reference to G8.
09-Jan-2012 From Version 34 to 35 Removed Removed a reference to G8.
14-Nov-2011 From Version 33 to 34 Changed Insight Management and HP Insight Foundation were revised
in HP Insight management software
Optimized, Standard and Basic Care Packages were updated
in Service and Support
HP Tape Backup was revised in Related Options
Note was added to Power Cords
29-Sep-2011 From Version 32 to 33 Changed Revisions made in the Configuration Information and
Related Options sections.
26-Sep-2011 From Version 31 to 32 Changed Power Supplies, Cisco MDS 9124e Fabric Switch for HP c-
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 47
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
Class BladeSystem, HP Ultrium Tape Blades and HP Care
Pack Services were revised.
30-Aug-2011 From Version 30 to 31 Changed Power Distribution Units were revised in Configuration
Information Factory Integrated Models
Product descriptions were revised throughout Related
Options
29-Jun-2011 From Version 29 to 30 Changed Changes were made within North America and Canada only.
24-Jun-2011 From Version 28 to 29 Changed Changes were made throughout, including removing HP SAS
Switches from Related Options and adding HP USB Keyboard
and Mouse to HP Rack Options.
23-Jun-2011 From Version 27 to 28 Changed Link was corrected in Service and Support.
03-Jun-2011 From Version 26 to 27 Changed Changes were made within North America and Canada only.
29-Apr-2011 From Version 25 to 26 Changed Changes made to revise the Service and Support section
along with other changes to the Overview, Configuration
Information and Related Options sections.
14-Feb-2011 From Version 24 to 25 Changed HP BladeSystem BLc7000 c-Class Server Blade Enclosures,
HP Insight Software, HP Virtual Connect Enterprise Manager,
HP Uninterruptible Power Systems, HP Rack Series and HP
Tape Backup product descriptions were revised
HP Virtual Connect FlexFabric 10/24 Enterprise Edition for
BladeSystem c7000 and HP Virtual Connect FlexFabric
10Gb/24-port Module for c-Class BladeSystem were added
to HP BladeSystem c-Class Network Interconnects
HP SB40c with (4) 300GB SAS SFF Bundle was added to HP c-
Class Storage Blades
TFT7600 Rackmount Keyboard Monitor, USB Interface
Adapter - 1 Pack, USB Virtual Media Interface Adapter and
Serial Interface adapter - 1 pack with power supply were
removed from HP Rack Options
08-Oct-2010 From Version 23 to 24 Changed HP Tape Backup and HP Care Pack Services were revised
Service and Support was added
HP Optical Drives was added to Related Options
10642G2 and 10647G2 1200 mm Shock Racks were added
to HP Rack Series
HP TFT7600 G2 KVM Console Rackmount Keyboard Monitors
were added to HP Rack Options
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem was removed from HP BladeSystem c-Class
Network Interconnects
2x1x16 IP Console Switch with Virtual Media was removed
from HP KVM Switch Options
HP Disk Backup was removed from Related Options
02-Jul-2010 From Version 22 to 23 Removed HP Virtual Connect FlexFabric 10/24 Enterprise Edition for
BladeSystem c7000 was removed from HP BladeSystem c-
Class Network Interconnects.
25-Jun-2010 From Version 21 to 22 Removed Removed a reference to an unavailable product.
21-Jun-2010 From Version 20 to 21 Changed HP BLc Virtual Connect FlexFabric 10Gb/24-port Module
Option and HP Virtual Connect FlexFabric 10/24 Enterprise
Edition for BladeSystem c7000 were added and HP
BladeSystem c-Class Virtual Connect 1Gb SX SFP Option Kit
and RJ-45 SFP Option Kit, HP GbE2c Layer 2/3 Ethernet
Blade Switch Advanced Functionality Software, HP 1:10 GbE
BLc Advanced Functionality Software, HP 10Gb Ethernet BL-
c Switch and HP 10GbE BLc Advanced Functionality Software
were removed from HP BladeSystem c-Class Network
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 48
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
Interconnects
HP 6X 2400W Platinum Efficiency FIO Power Supply and HP
2400W Platinum Hot-Plug Power Supply were added to HP
Power Supplies
NOTE was added to Step 4
HP 4Gb Virtual Connect Fibre Channel Module for c-Class
BladeSystem, HP Brocade 4/12 SAN Switch and 4/12 SAN
Switch Upgrade LTU and HP Brocade 4/24 SAN Switch and
4/24 SAN Switch Power Pack were removed
HP Insight Control, No Media 1-Server License including 1
year of 24x7 Technical Support and Updates was removed
from HP Insight Software
HP StorageWorks MSL2024 2 LTO-2 Ultrium 448 SCSI Drive
Library, HP StorageWorks MSL4048 1 LTO-3 Ultrium 960
SCSI Drive Library and 960 4 GB FC Library and HP
StorageWorks Virtual Library Systems were removed from
HP Tape Backup
19-Feb-2010 From Version 19 to 20 Changed HP Power Supplies, HP Insight Control, HP Enclosure, HP
Cooling Options, HP Uninterruptible Power Systems, HP
Tape Backup and HP Disk Backup were revised throughout
the QuickSpec.
25-Nov-2009 From Version 18 to 19 Changed Minor edits were made within the QuickSpec.
16-Nov-2009 From Version 17 to 18 Changed Changes were made throughout the QuickSpec.
02-Oct-2009 From Version 16 to 17 Changed Changes made throughout the QuickSpec except for the
Storage and Technical Specifications sections.
14-Aug-2009 From Version 15 to 16 Changed Revised Step 5 of the Configuration Information Factory
Integrated Models section
Added a NOTE for HP c7000 Onboard Administrator with
KVM to Step 4 of the Configuration Information Factory
Integrated Models section and c7000 Enclosure Options in
the Related Options section
Removed HP c7000 Redundant Onboard Administrator
Options from Step 4 of the Configuration Information
Factory Integrated Models section and c7000 Enclosure
Options in the Related Options section
17-Jul-2009 From Version 14 to 15 Changed Revisions were made in the HP BladeSystem c-Class
Overview section, Configuration Information Factory
Integrated Models section and to the Related Options
section.
03-Jul-2009 From Version 13 to 14 Changed Corrected Part Number for HP BLc7000 Insight Control suite
for Linux 16 License in Step 3 of the Configuration
Information Factory Integrated Models section.
02-Jun-2009 From Version 12 to 13 Added All c7000 enclosures support both models of Onboard
Administrator to NOTE in Step 4 of the Configuration
Information Factory Integrated Models section
Part numbers starting with 507 to NOTE in HP BladeSystem
InfiniBand Interconnects in Step 5 of the Configuration
Information Factory Integrated Models section
NOTE to HP c7000 Redundant Onboard Administrator
Options for c7000 Enclosure Options in the Related Options
section
Changed Updated HP BladeSystem Power Sizer in the HP
BladeSystem c-Class Overview section
Tape Blades were changed to HP Ultrium Tape Blades in the
Related Options section
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 49
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
29-Apr-2009 From Version 11 to 12 Changed Changes affected the North America and Canada versions
only. Just the date and version were changed in the
Worldwide version.
27-Apr-2009 From Version 10 to 11 Changed Changes were made throughout the QuickSpec.
30-Mar-2009 From Version 9 to 10 Added Active Cool 200 Fan and HP ProLiant Onboard Administrator
throughout the QuickSpec
HP StorageWorks 3Gb SAS BL Switch and HP 4x QRD IB
Switch Module for HP c-Class BladeSystem to Step 5 of the
Configuration Information Factory Integrated Models section
and Related Options section
HP 14.4 kVA Modular PDU to Step 6 of the Configuration
Information Factory Integrated Models section
Changed Completely revised Insight Control Suites throughout the
QuickSpec and Server Management Stand Alone Products in
the HP BladeSystem c-Class Overview and Related Options
sections and Core Infrastructure Management and URL for
HP BladeSystem Power Sizer in the HP BladeSystem c-Class
Overview section
Revisions were made throughout Step 2 of the Configuration
Information section
Removed NOTE from HP BladeSystem c-Class c7000
Enclosure in the HP BladeSystem c-Class Overview section
and 10642 G2 (42U) Rear Extension Kit and HP Modular
Cooling System from the Related Options section
26-Jan-2009 From Version 8 to 9 Added NOTE for HP 2400W High Efficiency Hot Plug Power Supply
in Step 2 of the Configuration Information Factory
Integrated Models and Related Options sections
HP StorageWorks SB920c Tape Blade to HP c-Class Tape
Blades in the Related Options section
HP Airflow Optimization section to the Related Options
Changed HP Insight Control Environment for Linux section of HP
Insight Control Environment for BladeSystem Management
Suites in the Related Options section
Updated HP Rack 10000 G2 Series in the Related Options
section
Minor formatting and grammatical changes were made
within Step 5 of the Configuration Information Factory
Integrated Models and the Technical Specifications sections
17-Nov-2008 From Version 7 to 8 Changed Changes were made to the following sections:
Overview:
What's New
At A Glance
HP BladeSystem c-Class Overview:
Rack Airflor Requirements
Server Management Stand Alone Software
Configuration Information Factory Integrated Models
Step Two
Step Five
Step Six
Related Options
Changes were made throughout this section
Technical Specifications
HP Blade System
Power
15-Sep-2008 From Version 6 to 7 Added SAS Enterprise drives have a 3 year warranty regardless of
the system in which they are installed to the Warranty
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 50
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
section of the At A Glance
HP 1:10 GbE BLc Advanced Functionality Software
HP 10Gb Ethernet BL-c Switch
HP GbE2c Layer 2/3 Ethernet Blade Switch Advanced
Functionality Software
Changed Server Management Stand Alone Software Product
NOTES section for the following:
HP Insight Control Environment for BladeSystem
Management Suite
HP Virtual Connect Enterprise Manager
HP PCI Expansion Blades
HP c-Class Tape Blades
HP StorageWorks All-in-One Storage Systems
Rack 10000 G2 Series
Tape Libraries
Power Cords
Completely revised the Uninterruptible Power Systems -
Rack
Width Dimension for the HP BladeSystem c7000 Server
Blade Enclosure
08-Aug-2008 From Version 5 to 6 Added 2m/6ft IEC C20-C19 jumper cord to the c-Class Power Supply
section in Step 2 of the Configuration Information Factory
Integrated Models and to the c7000 Power Options section
of the Related Options
HP 17.3 kVA Modular PCU and HP22 kVA Modular PDU to the
HP Modular Power Distribution Units section in Step 6 of the
Configuration Information Factory Integrated Models
-48V DC Power to Power Cords in the Power section of the
Technical Specifications
Changed Power Cords section in the Related Options
HP Single Phase and 3-Phase UPS sections in the Related
Options
14-Jul-2008 From Version 4 to 5 Changed Changes were made to the following sections:
HP BladeSystem c-Class Overview/Insight Control
Environment for BladeSystem Management Suite
HP BladeSystem c-Class Overview/Server Management
Stand Alone Software Product - ProLiant Essentials
Configuration Information Factory Integrated Models/HP
BladeSystem
c-Class SAN Interconnects
Configuration Information Factory Integrated Models/PDU
cords
Related Options/HP BladeSystem c-Class SAN Interconnects
Related Options/HP Insight Control Environment for
BladeSystem Management Suite
Related Options/Server Management Stand Alone Software
Product - ProLiant Essentials
Related Options/Power Cords
Removed Options were removed from the following sections:
Related Options/Tape Libraries
Related Options/HP KVM Switch Options
Technical Specifications/Power
12-May-2008 From Version 3 to 4 Changed Changes were made throughout the Overview, HP
BladeSystem c-Class Overview, Configuration Information
and Related Options sections.
11-Feb-2008 From Version 2 to 3 Changed Changes were made throughout the QuickSpec.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 51
QuickSpecs HP BladeSystem c7000 Enclosure
Summary of Changes
05-Oct-2007 From Version 1 to 2 Changed Updated the description for part number AF916A.
© Copyright 2015 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.
Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries.
AMD Opteron™ is a US registered trademark of AMD Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.
c04128339 — DA – 12810 North America— Version 62 — February 9, 2015 Page 52